5.1  Programming Temperatures 
 
You are able to program the setpoint temperature of both the air heater and the heater plate via the computer 
interface.  The heater plate factory default is set to the McDonald’s standard of 160
°F.  The air heater factory 
default is set to the McDonald’s standard of 220
°F.  If the factory default temperature settings are acceptable, skip 
to Section 7.2, Page 6. 
 
Ensure that the HLZ computer is in the OFF position (nothing in the display).   
Press 
, then enter 1, 2, 3, 3.  Use the numerals in the upper right-hand corner of each key. 
 
 
Press 
, then 
 
 
The display will read SET and the LEDs on both the Heater Plate button (1) and the Air Heater button (4) will 
light (see previous diagram, HLZ Computer).  Press the button that corresponds to the heater you wish to 
program. 
 
Press the Up and Down Arrow Keys to achieve the desired set-point temperature, then press the Check button 
once.  Both heater LEDs will again light.  
 
 
Press 
 or 
 to get desired setpoint, then press 
 to lock the temperature in. 
 
 
When both heaters are programmed, press 
 again to store the programmed setpoints and exit the 
programming mode OR press either of the 
 buttons (1 or 4) to change the setpoint temperature for a heater.  
Program as previously described. 
 
Heater Plate
Temperature
Switch (1)
ON/OFF Switch
Down Switch (2)
Up Switch (3)
Check or
Program Switch
Air Heater
Temperature
Switch (4)
Display