Troubleshooting  
6-5
Compaq Confidential – Need to Know Required
Writer: Debbie McRill  Project: Compaq DAT AutoLoader Reference Guide  Comments: 
Part Number: 326817-003  File Name: g-ch6 Troubleshooting.doc  Last Saved On: 12/20/99 2:42 PM
For Microsoft Windows NT Systems
NOTE:  The following procedures apply only for Microsoft Windows NT 4.0 and above.
 
1. Confirm that the SCSI controller software driver has been installed and
started.
 
a. Use the Windows NT Setup program or SCSI Adapters applet on the
Control Panel to determine if the driver is installed.
 
b. Use the Devices or SCSI Adapters applet on the Control Panel to
determine if the driver is started.
 
c. If necessary, reinstall the driver.
 
2. Confirm that the DAT AutoLoader driver has been installed and started.
 
a. Use the Windows NT Setup program or Tape Devices applet on the
Control Panel to determine if the driver is installed.
 
b. Use the Devices or Tape Devices applet on the Control Panel to
determine if the driver is started.
 
c. If necessary, reinstall the driver.
For SCO OpenServer Systems
 
1. Verify that the tape driver is configured in the kernel.
 
a. Use the 
HWCONFIG
 command or view the bottom of the file,
/usr/adm/messages,
 to determine whether the driver is installed or to
determine the current tape parameters.
 
b. Use the 
MKDEV TAPE
 command to install the driver in the kernel or to
modify the current tape parameters.
 
2. If you are using the DAT AutoLoader to install SCO OpenServer and a
Fast SCSI-2 Controller, verify that the DAT AutoLoader is connected to
the Fast SCSI-2 Controller.