Dexter Russell T1200 ユーザーズマニュアル

ページ / 17
MODEL T1200 
 
 
DEXTER
   
 
 
 
LAUNDRY,                                                                                                                                         
INC. 
 
 
 
 
INSTALLATION INSTRUCTIONS 
 
All washers must be installed in accordance with all local, state and national building, 
electrical, plumbing and other codes in effect in the area. 
 
 
 
 
WARNING - THESE INSTALLATION AND SERVICING INSTRUCTIONS 
ARE FOR USE BY QUALIFIED PERSONNEL ONLY.  TO AVOID INJURY 
AND ELECTRICAL SHOCK DO NOT PERFORM ANY SERVICING 
OTHER THAN THAT CONTAINED IN THE OPERATING 
INSTRUCTIONS, UNLESS QUALIFIED. 
 
 
 
FOUNDATION REQUIREMENTS 
 
This machine is designed for use on or over bare concrete floor - not to be used above 
combustible flooring.  The washer must be securely bolted and grouted to a substantial concrete 
floor, or mounted and grouted upon a suitable base that is securely bolted and grouted to a 
substantial concrete floor.  CARE MUST BE STRESSED WITH ALL FOUNDATION WORK 
TO INSURE A STABLE UNIT INSTALLATION, ELIMINATING POSSIBILITIES OF 
EXCESSIVE VIBRATION.  All installations must be made on sound concrete floors, 8 inches 
(203 mm) or thicker.  Anchor bolts or expansion anchors must be of a quality grade and a 
minimum of 3/4-inch (19 mm) diameter.  Six bolts are required to mount the washer to the steel 
base or concrete pad. 
 
MOUNTING 
 
A concrete pedestal or steel-mounting base that elevates the machine approximately 4 inches 
(102 mm) above the floor level is recommended to provide easy access to the loading door.  
Allow a minimum of 24 inches (610mm) of clearance behind the rear of the machine, to provide 
access for motor removal.  Refer to Fig. 1-1 and 1-2 for machine bolt-down dimensions. 
 
If an elevated concrete pedestal is desired, it should be embedded into the existing floor.  Anchor 
bolts should be 3/4" x 8" (19 mm x 200 mm), grade 8 or better, headed by a 4 inch (10 cm) 
square fish plate and should protrude 2 1/2” (64 mm) above the finished surface of the pedestal.  
EXPANSION ANCHORS ARE NOT RECOMMENDED FOR USE IN CONCRETE 
PEDESTALS, BECAUSE THE ANCHORS ARE TOO CLOSE TO AN EDGE, CAUSING IT 
TO BREAK OUT.  (See Fig. 1-1 and 1-3.)