HP 160 G6 490455-421 ユーザーズマニュアル

製品コード
490455-421
ページ / 55
with a fan fault or above 30°C (86°F).
Non-operating
-30° to 60°C (-22° to 140°F). Maximum rate of
change is 20°C/hr (36°F/hr).
Relative Humidity
(non-condensing)
Operating
10 to 90% relative humidity (Rh), 28°C (82.4°F)
maximum wet bulb temperature, non-
condensing.
Non-operating
-30° to 60°C (-22° to 140°F). Maximum rate of
change is 20°C/hr (36°F/hr).
Altitude
Operating
3050 m (10,000 ft). This value may be limited by
the type and number of options installed.
Maximum allowable altitude change rate is 457
m/min (1500 ft/min).
Non-operating
9144 m (30,000 ft). Maximum allowable altitude
change rate is 457 m/min (1500 ft/min).
Acoustic Noise
Listed are the declared A-Weighted sound power levels (LWAd) and declared
average bystander position A-Weighted sound pressure levels (LpAm) when
the product is operating in a 23°C ambient environment. Noise emissions were
measured in accordance with ISO 7779 (ECMA 74) and declared in accordance
with ISO 9296 (ECMA 109).
Idle
 
LWAd
6.3B
LpAm
48dBA
Operating
 
LWAd
6.3B
LpAm
48dBA
Emissions Classification
(EMC)
FCC Rating
Class A
Normative Standards
CISPR 22; EN55022; EN55024; FCC CFR 47, Pt 15;
ICES-003; CNS13438; GB9254; K22;K24; EN
61000-3-2; EN 61000-3-3; EN 60950-1; IEC
60950-1
NOTE: Product conformance to cited product specifications is based on
sample (type) testing, evaluation, or assessment. This product or family of
products is eligible to bear the appropriate compliance logos and statements.
QuickSpecs
HP ProLiant DL160 Generation 6 (G6)
Technical Specifications
DA - 13247   Worldwide — Version 59 — September 24, 2012
Page  53