Delhi Industries DSQ-D-12 プリント

ページ / 2
Electrical 
Warning:  Ensure power supply is disconnected & locked out prior to making electrical connections. 
 
Before connecting the motor to the electrical supply, check the electrical characteristics and wiring instruc-
tions as indicated on the motor nameplate or as shown below.  Complete electrical connections as indicated. 
 
Warning:   A ground wire must be connected from the motor housing to a suitable electrical ground.
 
Operation 
1.
Complete the electrical connections, energize the unit momentarily and ensure proper wheel  rotation. 
2.       Apply full power.                                                                                                     
3.      With all ducts attached, the access doors in place and the air system in full operation, measure the             
         motor current and ensure that it is less than the rated full load motor amperage as indicated on the   
          motor nameplate.
 
Motor Wiring Diagram 
 
DSQ-D-10, 12 & 13 
MOTOR WIRING - SINGLE SPEED 
 
                                                      
      
                                                      
 
                                                      
 
 
DSQ-D-15 
MOTOR WIRING - TWO SPEED 
 
                                               
Speed Control Wiring Diagram  
For DSQ-D10, 12 & 13 Single Speed Motors Only 
 
CONNECTIION DIAGRAM FOR 2 WIRE CONTROL 
 
WARNING:  Power must be turned off before wiring.  Connect control in series 
with motor and line voltage - never connect control across line. 
 
Minimum speed adjustment - factory set. 
 
See installation instructions provided with speed control. 
Maintenance 
         Ensure power supply is disconnected and locked out prior to performing maintenance. 
1.
Inspect and tighten the wheel set screw after the first 50 to 100 hours of operation and periodically  
          thereafter. 
2.      Follow the motor manufacturer's instructions for motor lubrication.  Remove any excess lubrication.  
3.
Clean the blower wheel periodically.  Material build up on the blades can cause wheel imbalance which 
may result in wheel or motor bearing failure.
                                                  
 Warranty    
Delhi Industries Inc. Air Moving Products are guaranteed for a period of one year against manufacturing     
defects in material and workmanship when operating under normal conditions.  Liability is limited to the       
replacement of defective parts. Labour and transportation costs 
are not included.
 
Delhi Industries Inc, 523 James Street, Delhi, Ontario N4B 2Z3                                                                   SE-42 
Tel: (519)582-2440       Fax: (519)582-0581      www.delhi-industries.com                                      October 2006 
Parts List 
 
1
Cabinet 
2
Side Access Panel 
3
Motor 
4
Wheel 
5
Inlet Venturi