Figure 10 illustrates the plug-in board required for the 2X redundant return option. Jumpers 
J
5
 
and 
J
6
 are shown in the correct position. Jumper 
J
6
 enables signal flow to output connector 
J
8
 (Tx2) when in the left-most position. Jumper 
J
5
 terminates input connector 
J
3
 (
IN
2
) when only 
a single RF input is used. 
Figure  10  
2X redundant return board 
J9
T3
Q1
C15
R1
J4
J1
J2
C9
T1
J5
J6
C10
TERM
TERM
J7
J8
C11
R7
T2
C12
J3
IN1
IN2
TX2
TX1
R2
R1
1
C5
C4
R13
R16
R10
R4
C7
C8
C13
C6
R3
R8
R5
R1
2
C18
R1
4
R15
L1
C16
C1
9
C14
C17
R6
C2
C1
C3
SM
J5
J6
 
Figure 11 illustrates the signal flow through the 2X redundant return board: 
Figure  11  
2X redundant return – signal flow 
Loss = 0.9 dB 
J6
-0.5 dB 
-3.5 dB 
+7.5 dB 
-3.5 dB 
TX2
TX1 SM
J5 
IN2
IN1
 
To set up the split redundant return option: 
Confirm that SG4-DRT-2X transmitters are installed in lid optics slots 3 and 4, and 5 and 6. 
Confirm that a 2X redundant return board is installed in return configuration locations 2 
and 3 as illustrated in Figure 8. 
Position 
J
6
 in the left-most position on each configuration board to enable the output to Tx2. 
Connect an RF cable from connector TX1 on the 2X redundant return board in configuration 
location 2 to CH B of the transmitter in lid optics slots 3 and 4. 
Connect a second RF cable from connector TX2 on the 2X redundant return board in 
configuration location 2 to CH B of the transmitter in lid optics slots 5 and 6. 
Connect an RF cable from connector TX1 on the 2X return redundant board in configuration 
location 3 to CH A of the transmitter in lid optics slots 3 and 4. 
Connect a second RF cable from connector TX2 on the 2X return redundant board in 
configuration location 3 to CH A of the transmitter in lid optics slots 5 and 6. 
SG4-DRT-2X Installation Sheet