Motorola SG4-DRT-2X ユーザーズマニュアル

ページ / 18
 
 
STARLINE 13 
Figure 13 illustrates the segmented return plug-in board. 
Figure  13  
Segmented return board 
TX1
SM
TX2
R1
J3
J5
R4
R7
R6
R9
R8
J7
J4
IN2
IN1
R5
R2
R3
T1
R10
J6
C1
2
C
12
C1
1
C7
C9
C1
0
C6
C8
C3
C2
C1
R1
1
 
Figure 14 illustrates the signal flow through the segmented return board: 
Figure  14  
Segmented return board – signal flow 
-0.5dB 
Loss = 0.9 dB 
TX1
TX2
IN2
IN1
SM
Pad 
Pad 
 
To set up the segmented return option: 
Confirm that dual SG4-DRT-2X return transmitters are installed in lid optics slots 3 and 4 
and 5 and 6. 
Confirm that a segmented return board is installed in the return configuration locations 2 
and 3 as illustrated in Figure 11. 
Connect an RF cable from connector TX1 on the segmented return board in configuration 
location 2 to CH B of the SG4-DRT-2X in lid optics slots 3 and 4. 
Connect an RF cable from connector TX2 on the segmented return board in configuration 
location 2 to CH A of the SG4-DRT-2X in lid optics slots 3 and 4. 
Connect an RF cable from connector TX1 on the segmented return board in configuration 
location 3 to CH B of the SG4-DRT-2X in lid optics slots 5 and 6. 
Connect an RF cable from connector TX2 on the segmented return board in configuration 
location 3 to CH A of the SG4-DRT-2X in lid optics slots 5 and 6. 
 
The RF cable should be approximately eight inches long and have red boots on the connector 
signifying the return path. 
If necessary, connect the appropriate return RF cables from the SG4-RF modules to each 
segmented return board. 
Ensure that the PIC cable is properly connected to the lid and power distribution board in 
the housing base. 
 
SG4-DRT-2X Installation Sheet