Moeller Marine XControl PLC System AWB2700-1428GB ユーザーズマニュアル

ページ / 54
12/01 AWB2700-1428GB
Basic menu
45
After a power failure, the PLC will start up in the mode specified 
by the OMS setting when the password was activated, irrespective 
of the current setting. The status and parameters can only be 
modified after the password is entered.
Entering and activating a password:
X
Choose DEVICE/SECURITY/PASSWORD.
X
Turn the MSS until the display shows EDIT.
X
Press the MSS.
X
Turn and press the MSS to enter each character of the pass-
word. You can enter up to 10 alphanumeric characters.
X
Pressing the MSS with ENTER displayed will accept the pass-
word.
X
Select menu item ACTIVATE.
X
Turn the MSS until the display shows ACTIVATE.
X
Press the MSS. The word ENTER will appear on the display.
X
Press the MSS once more. The display will return to the basic 
menu.
Operation after starting up the PLC:
After the startup the display will show, for example:
The program is processed and the RUN LED is lit.
You can only reach the main menu by entering the password:
X
Turn the MSS so that the display shows PASSWORD. Press the 
MSS so that the display shows:
If the position of the OMS was changed, a message will indicate 
how the OMS should be set, such as Key: ”RUNP”. Switch the 
OMS to this position to clear the message.
X
Enter the password.
X
Turn the MSS until the display shows EDIT.
X
Turn and press the MSS to enter each character of the pass-
word. The text ENTER will appear after the password has been 
entered.
X
Press the MSS. The display will switch to the basic menu and the 
submenus.
Entering an incorrect password will return you to the basic menu.
LANGUAGE
SOFTWARE
This menu shows the software version of the individual modules. 
The CPU module is not listed.
Example of an operator module:
Turning the MSS will display the modules XC_XION and 
XC_NET_0/1/2.
The number 1 in the designation XC-NET-1 indicates the module 
(address):
Time
PLC status (irrespective of OMS)
Program name
Menu entry
! =Event
+ = Password active
R = RUN (OMS)
PASSWORD:
 BACK
ACTIVATE:
DEACTIVATE
 BACK
17:10:37 !+R
RUN
PRONAM.PRO
MAIN MENU
PASSWORD:
***
BACK
Number
(Hardware) address of the module
0
CE000
1
CC000
2
D4000
LANGUAGE:
 ENGLISH
 GERMAN
 BACK
XC_SYS
V01.00A
BACK