HORIZONTAL BAR
 
Using the Digital Sight Gauge display, the liquid level in the server can be 
monitored by watching the horizontal bars. The 1.0 gallon display is equipped with 
4 bars and the 1.5 gallon with 6 bars to represent the level inside the dispenser. 
(each bar represents a quart, or one quarter of a gallon)
 
All four/six bars will be displayed when the server is full. When the level of 
the liquid drops to a certain level, the highest bar on the display will no longer be 
illuminated. These bars will continue to disappear as the level inside the dispenser 
drops. (See Fig. 1)
COUNTDOWN TIMER
 
The Digital display is set to count down 2:00 hours. The display counts down in one minute increments, flashing at 15 
minutes and continuing to flash once it reaches 0. (See Fig. 1)
TIMER RESET
  The display will reset to 0 when any of the following occurs:
•  The liquid level in the server is increased by 1 bar for a sustained period of time. (brewing into, or adding additional
liquid to existing beverage)
•  A fresh new beverage is brewed into the server.
•  When the contact pins of the sensor assembly are disengaged from the display for more than 20 seconds.
DISPLAY OFF
 
When the sensor assembly on the server is removed or loosened for more than 20 seconds, the display on the Digital 
Sight Gauge breaks contact with the pins on the surface of the server. When this happens, the outline that surrounds the 
Horizontal Level Bars will flash on and off and the time disappears. This indicates that the display has been disengaged 
from the probe and cannot receive data.
 
When the display is in place and engaged, but the server is empty, the outline surrounding the Horizontal Level Bars 
will be on but not flashing and the Freshness Time will be at 0 and flashing. All other portions of the display will not be 
visible. This indicates the display is engaged and ready to receive data from the probe, but the server is empty.
 
The only time the display will be completely blank, is when the batteries have been removed or have expired. (See the 
“Battery Replacement” section for additional information.)
FRESHNESS TIME
 
This unit is factory set to count down to 15 minutes, and begin flashing. If a reset condition has not occurred, it will 
continue to flash and count down to 0.
 
LOW BATTERY INDICATOR
 
When the batteries in the display unit are running low, the display is also equipped with a battery icon. The upper most 
bar used in monitoring liquid levels, will begin to flash in the shape of a battery to indicate that it is time to replace the 
batteries. (See FIG. 1)
DIGITAL DISPLAY
 
The Digital ThermoFresh Server is equipped with a digital probe and display called a Digital Sight Gauge. The probe 
contains a circuit board designed to sense liquid levels & hold times. During the monitoring process, the probe sends 
information to the display. The display then allows the user to monitor the liquid level and freshness (hold time) of the 
beverage held in the server.
FIG. 1
43240.11 030912