Bunn Water Heater DV PC ユーザーズマニュアル

ページ / 9
3
CONTENTS
 Warranty 
.......................................................2
 Introduction 
..................................................3
 User 
Notices 
.................................................3
 Electrical 
Requirements 
................................4
 Plumbing 
Requirements 
...............................5
 Initial 
Set-Up 
.................................................5
 Programming 
................................................6
 
Draining the Dispenser ..................................8
 Cleaning 
........................................................8
 
INTRODUCTION
This equipment heats and dispenses water on demand for beverages and cooking purposes.  It has a panel 
above the faucet that indicates the status of the dispenser.  This equipment is for indoor use, either wall-mounted 
(H5E/H5X/H5-PC only) or on a sturdy counter or shelf.
39338.1.1 072409
12593.0000
00831.0000
37881.0000
USER NOTICES
The notices on this dispenser should be kept in good condition.  Replace unreadable or damaged labels.
00656.0000
To reduce the risk of electric shock,
do not remove or open cover.
No user-serviceable parts inside.
Authorized service personnel only.
Disconnect power before servicing.
This equipment must be installed to comply 
with the International Plumbing Code of the 
International Code Council and the Food 
Code Manual of the Food and Drug Adminis-
tration (FDA). For models installed outside 
the U.S.A., comply with the applicable 
Plumbing /Sanitation Code.
WARNING 
!
Fill water tank before turning - on -  
thermostat or connecting appliance 
to power source. 
Use only on a properly protected 
circuit capable of the rated load. 
Electrically ground the chassis. 
Follow national/local electrical codes. 
Do not use near combustibles. 
FAILURE TO COMPLY RISKS EQUIPMENT 
DAMAGE, FIRE, OR SHOCK HAZARD 
READ THE ENTIRE OPERATING MANUAL 
BEFORE BUYING OR USING THIS PRODUCT 
THIS APPLIANCE IS HEATED WHENEVER 
CONNECTED TO A POWER SOURCE 
00831.0000F  3/98   ©1998  BUNN-O-MATIC CORPORATION 
!  WARNING
Hot Water
Use With Care
NOTICE
ALL COMPONENTS ARE
200 TO 240 VOLT A.C.
Replace only with
components listed in the
accompaning literature
rated for the same
voltage
12537.0000
120V
120/208-240V
00831.0000
Optional Field Wiring
120 V,  15.4 A,  1850 W
1PH,  2-Wire + GND,  60HZ
Optional Field Wiring
120/208-240 V,  16.9 A,  4050 W
1PH,  3-Wire + GND,  60HZ
29710.0000
29710.0000
00824.0000
00824.0001