Unity 4600 User’s Manual 
Audio FP Monitor Selection Screen as default
For two minutes, or until 
ESC
 is pressed, the Level 2 Audio FP Monitor Selection screen is 
the default if the unit features a front-panel audio monitor jack and the user plugs in a ¼” 
stereo phone plug. Note that this is NOT usually a first-level screen, unlike other default 
examples.
On the home screen, the
 (right-pointing arrow) field will quickly flash (a half-second ON 
and a half-second OFF) to signal the user that the right arrow button is active for user 
control. Pressing either the left or right arrow buttons will cause the 
Unity 4600
 to display the 
other top-level screens in succession. If there are current alarm and warning indications, the 
text "See alarms" or "See Warnings" will appear before the arrow and pressing the right 
arrow will display the applicable alarm or warning message(s).
Interpreting 
LEDs
Front panel LEDs
 provides the meaning of the color and state of each LED.
 Figure 3.5:   LED Indicators
Table 3.2: Front-panel LED Indicator Descriptions
Indicator Label
Color and State*
Meaning
CARRIER
GREEN constant
Unit has demod and FEC lock on the RF carrier
Off
Unit does not have demod and FEC lock on the RF carrier
TRANSPORT
GREEN constant
Unit recognizes a valid transport stream
Off
Unit does not recognize a valid transport stream
COMPEL
®
GREEN constant
COMPEL control stream received within last two minutes 
(including keep-alives) while locked continuously on the current 
transport stream for >2 minutes
GREEN flash
Unit has had a verified transport stream for >2 minutes and 
COMPEL is required but no valid COMPEL 
GREEN flutter
COMPEL has been addressed to unit within last 5 seconds 
(excluding keep-alives)
Off
Otherwise. Note that this LED must be OFF when there is no valid 
Transport stream OR COMPEL