There are installer selectable switches located on the bottom of the 2802CID base unit.  
These switches are hidden behind a plastic cover for security.  To locate, remove the 
plastic covers using a sharp pointer or paper clip as shown. 
Tone/Pulse Dialing Selector 
 
The 2802CID has the option to out -dial either in 
“touch-tone” or electronic rotary pulse mode.  
Simply slide the switch to the desired position 
associated to your dialing service.  Note:  the 
2802CID is factory preset to the “Tone” mode 
setting. 
Message Waiting  Selector 
 
The 2802CID can support 90VDC neon or low -
voltage LED (FSK compatible) message waiting 
systems.  Simply slide the switch to the desired 
position that is compatible with your PBX 
messaging system. Note:  the 2802CID is factory 
preset to the “Neon” setting. 
Line Voltage Selectors 
 
The 2802CID is designed to operate behind PBX telephone systems rated between 24 volts 
and 48 volts.  There are line voltage selector switches that must be set according to the PBX 
system rating that the 2802CID will be installed.  There are two (2) switches, the first for Line 
1 and the other for Line 2.  Each switch has three (3) setting options.  They are: “24V/48V/
OFF”.  Set the switches by simply sliding to the appropriate setting.  The ”OFF” setting is used 
to turn off the line if a line appearance is not wired to the telephone.   Note:  the 2802CID is 
factory set to the “24V” setting. 
SWITCH SETTINGS