Lodge Manufacturing GMD1-80N ユーザーズマニュアル

ページ / 47
All installations and services must be performed by qualified service personnel.
 
 37
TROUBLESHOOTING COMPLETE.
CHECK ALL
WIRING FOR
LOOSE
CONNECTIONS
IS LED LIGHT
ON INTEGRATED
CONTROL FLASHING?
DOES SYSTEM RUN UNTIL
THERMOSTAT IS SATISFIED?
DOES BURNER SHUT OFF
WHEN THERMOSTAT IS
SATISFIED?
CHECK FOR SHORT IN 
WIRE TO THERMOSTAT
AND CORRECT IF
NECESSARY.
DOES THE CIRCULATING
AIR BLOWER TURN OFF
AFTER THERMOSTAT IS
SATISFIED WITHIN
120 SECONDS?
Yes
Yes
No
No
Yes
No
Yes
Yes
IF LED FLASHES:
1 FLASH, THEN PAUSE   SYSTEM LOCKOUT
2 FLASHES, THEN PAUSE    PRESSURE SWITCH STUCK CLOSED
3 FLASHES, THEN PAUSE    PRESSURE SWITCH STUCK OPEN
4 FLASHES, THEN PAUSE    OPEN LIMIT SWITCH OR ROLLOUT SWITCH
6 FLASHES, THEN PAUSE    115 VOLT AC POWER REVERSED
7 FLASHES,  THEN PAUSE    LOW FLAME SENSE SIGNAL
8 FLASHES, THEN PAUSE    CHECK IGNITOR OR IMPROPER GROUNDING
CONTINUOUS FLASHING      FLAME HAS BEEN SENSED WHEN NO FLAME
         (NO PAUSE)                  SHOULD BE PRESENT (NO CALL FOR HEAT)
THE LED WILL ALSO FLASH ONCE AT POWER-UP.
CHECK COMPLETE SYSTEM OUT.
LED LIGHT STAYS ON CONTINUOUSLY,
COMPLETE FAILURE - REPLACE INTEGRATED CONTROL.