Bryan Boilers CLM-150-S150-GI ユーザーズマニュアル

ページ / 4
High effi ciency hot water and steam boilers
for commercial and industrial applications
Bryan fl exible tube boilers are ideally suited for both 
hot water and steam space heating systems as well 
as either high or low pressure process steam. In a 
range of sizes from 900,000 to 3,000,000 BTUH in-
put, Bryan CLM series fl exible tube boilers are ideal 
for many commercial, institutional and industrial 
applications. These include healthcare facilities; 
schools; apartments; churches; offi ce  buildings; 
correctional facilities; airports; sewage treatment 
plants; golf, tennis and fi tness clubs. Hospitals, 
dairies, restaurants, laundries, dry cleaners, food 
processing, tire recapping and metal plating are just 
a few of the many applications.
  All Bryan boilers are built in accor-
dance with the requirements of the ASME 
Boiler and Pressure Vessel Code.
Effi cient “Flexible Water Tube” 
design
The Bryan bent water tube provides rapid 
internal circulation — for maximum heat 
transfer and operating effi ciency. 
Easily replaceable tubes
Tubes are easily removable and replaceable without 
welding or rolling. Little service space is required.
No “Thermal Shock”
The fl exibility of the bent water tube design elimi-
nates all possible damage from "Thermal Shock" and 
from stresses caused by poor or unequal internal 
circulation. This is particularly important with forced 
hot water heating systems designed for higher tem-
peratures and greater temperature drops.
Steam Boilers: Section IV or I
Steam release area
Large, full-size steam drum provides for dry steam 
and stable water level.
High or low pressure construction
Boiler is constructed as standard for 15 psi or 150 
psi maximum working pressure. Also available for 
higher pressures to 300 psi.
Water Boilers: Section IV
High or low pressure construction
Boiler is constructed as standard for 
160 psi maximum working pressure at 
230°F operating temperature and 250°F 
design temperature. Also available for 
higher pressures to 250 psi, at 285°F 
operating temperature and 300°F design 
temperature.
Natural internal circulation
The water tube design and the large 
downcomer legs provide adequate internal circula-
tion without concern over exterior pumping condi-
tions. Low pressure drop through boiler.
Compact — minimum fl oor space
Requires less floor space than most boilers, 
minimum boiler room size. Since the tubes can be 
removed from one side, the boilers are available 
with right or left hand construction for common tube 
removal, further minimizing space needs.
  Shipped completely assembled and wired. Units 
can also be shipped "Knocked Down" for on-site 
assembly.
Bryan CLM Series Boiler Specifi cations
   
 
 NOMINAL OUTPUT 
STEAM 
HEATING 
APPROX. 
 
BOILER INPUT 
  
 
OUTPUT  SURFACE 
SHIP 
WT.
 
MODEL MBH 
(KW)
 
MBH (KW)   
BHP 
 LBS/HR* 
SQ. FT. (M²) 
LBS. (KG)
  CLM-90 
900 (264) 
720 (211)   
21 (206) 
742 (337) 
110 (10.2) 
1,450 (658)
  CLM-120 
1,200 (352) 
960 (281)   
29 (284) 
990 (449) 
145 (13.5) 
1,750 (794)
  CLM-150 
1,500 (440) 
1,200 (352)   
36 (353) 
1,237 (561) 
180 (16.7) 
2,050 (930)
  CLM-180 
1,800 (527) 
1,440 (422)   
43 (421) 
1,485 (674) 
215 (20.0) 
2,350 (1,066)
  CLM-210 
2,100 (615) 
1,680 (492)   
50 (490) 
1,732 (786) 
251 (23.3) 
2,650 (1,202)
  CLM-240 
2,400 (703) 
1,920 (563)   
57 (559) 
1,979 (898) 
287 (26.7) 
2,950 (1,338)
  CLM-270 
2,700 (791) 
2,160 (633)   
64 (627) 
2,227 (1,010) 
322 (29.9) 
3,500 (1,588)
  CLM-300 
3,000 (879) 
2,400 (703)   
72 (706) 
2,474 (1,122) 
360 (33.5) 
3,950 (1,792) 
NOTES: * Lbs. steam per hour from and at 212°F.