Dacor DR30GIFSNGH インストール手順
12
Gas Connection
WARNING
• Make sure the gas is turned off at the gas supply
valve before connecting the gas line.
• Verify that the gas supply meets specifications before
connection. See page 5.
• Do not apply excessive pressure when tightening gas
connections and fittings.
• Do not use Teflon tape or plumber’s putty on flexible
gas line connections.
• Test the gas lines for leaks as instructed before use.
If a leak is detected, open all doors and windows and
allow the gas to dissipate before fixing the leak and
testing the unit.
• Do not use a flame to check for leaks.
• The maximum gas supply pressure to the regulator
• The maximum gas supply pressure to the regulator
must never exceed 1/2 pounds per square inch (psi)
or 3.5 kPa.
• The range and its individual shutoff valve must be
disconnected from the gas supply piping system
during any pressure testing of that system at test
pressures in excess of 1/2 psi (3.5 kPa).
• The range must be isolated from the gas supply
piping system by closing its individual manual shutoff
valve during any pressure testing of the gas supply
piping system at test pressures equal to or less than
1/2 psi (3.5 kPa).
• For LP gas installations, the LP gas tank must have
its own high-pressure regulator in addition to the
pressure regulator installed on the range.
IMPORTANT: The installed gas pressure regulator is pre-
set at the factory for the type of gas intended for use with
the appliance. Verify that the appliance is compatible with
the type of gas available by checking the product data label
attached to the appliance. Ranges intended for use with
LP gases will have “LP” as a part of the model number.
Consult your dealer if the range is not compatible with your
gas supply.
1. Make sure the gas supply valve is in the off position
1. Make sure the gas supply valve is in the off position
and the range power cord is disconnected.
2. Connect a flexible gas supply line to the gas shut-off
valve previously installed on the stub out. The gas
line needs to be long enough to allow the range to be
pulled out for service.
3. Connect the gas line to the regulator on the back of the
range.
4. Turn all cooktop control valves to the
“OFF” position.
5. Turn on the gas supply valve and check
all lines and connections for leaks using a
soap and water solution or an electronic
gas leak detector.
6. Turn the gas supply off.
Gas Line
Connection
“OFF”
symbol on
knob
1/2” male NPT
connection*
Installation Instructions
* 3/4” male NPT connection may be used
if the adapter on the regulator is removed.