TROUBLESHOOTING PROCEDURES FOR MONSOON I
Issue
Cause
What to do
After installation, 
the unit doesn’t 
work.
1.  The power source is not turned ON.
1.  Make sure the circuit breaker and the unit’s 
power is ON.
2.  The power line and the cable locking connector 
is not connecting properly.
2.  Check the power connection with the unit is 
connected properly.
3.  The switch board and control board wires are 
disconnected.
3.  Make sure the wires between the switch board 
and control board are connected properly.
4.  The wires on control board are loose.
4.  Make sure the wires on the control board are 
connected properly.
5.  The switch board or control board is defective.
5.  Change the switch board or control board.
Light works, but 
blower is not 
turning.
1.  The blower wire is not connected. 
1.  Make sure the blower wire is plugged into the 
molex connector. 
2.  The thermally protected system detects if the 
blower is too hot to operate and shuts the blower 
down.
2.  The blower will function properly after the 
thermally protected system cool down.
3.  Damaged capacitor.
3.  Change the capacitor.
4.   Blower molex plug pin is not making contact.
4.   Disconnect the blower molex plug, check pins 
inside plug to see if pin is pushed inside the 
plug too far. Reseat pin if needed.
5.  The blower is defective, possibly seized. 
5.  Change the blower. 
The unit is 
vibrating.
1.  The blower is not secure in place.
1.  Tighten the blower in place.
2.  The hood is not secured in place. 
2.  Check the installation of the hood.
3.  Damaged blower wheel.
3.  Change the blower.
The unit is 
whistling.
1.   A fi lter is not in the correct position.
1.   Adjust the fi lters until the whistling stops.
2.   The duct pipe connections are not sealed or 
connected properly.
2.   Check the duct pipe connections to be sure all 
connections are sealed properly.
The blower is 
working, but the 
lights are not.
1.  The light bulb is loose.
1.  Tighten the bulb and make sure it’s secure.
2.  Defective halogen bulb.
2.  Change the halogen bulb.
3.  The light bulb plug is disconnected.
3.  Connect the light bulb plug.
The hood is 
not venting out 
properly.
1.  The hood might be hanging too high from the 
cook top.
1.  Adjust the distance between the cook top and 
the bottom of the hood within 26” and 36” 
range.
2.  Wind from an opened window or opened 
doors in the surrounding area are affecting the 
ventilation of the hood.
2.  Close all the windows and doors to eliminate 
outside wind fl ow.
3.  Blockage in the duct opening or duct work.
3.  Remove all the blocking from the duct work or 
duct opening.
4.  The direction of duct opening is against the wind.
4.  Adjust the duct opening direction.
5.  Using the wrong size of ducting.
5.  Change the ducting to correct size.
Filter is vibrating.
1.  Filter is loose.
1.  Adjust or change the fi lter.
2.  Spring clip is broken on the fi lter.
2.  Change the spring clip.
RF Remote 
control does not 
work
1.  Battery is dead.
1.  Replace battery with type A23 12v.
2.  Poor communication with the power pack.
2.  Remote control must be within 15 ft of insert.
3.  RF remote lost communication with the insert.
3.  Reset insert and remote by switching power 
off at the circuit breaker for 5 minutes. Pace 
remote on counter top near the insert and 
switch the circuit breaker back on.