Gaggenau AI442720 インストールガイド
15
Connect appliance
Notes
‒
With operation in extraction air mode , a back-
pressure flap should be installed. If no back-
pressure flap is included with the appliance, it can
be ordered from a specialist retailer.
pressure flap should be installed. If no back-
pressure flap is included with the appliance, it can
be ordered from a specialist retailer.
‒
If the exhaust air is conveyed through the outer wall,
a telescopic wall box should be used.
a telescopic wall box should be used.
‒
If an aluminum pipe is used, smooth the connection
area beforehand.
area beforehand.
Establishing the connection for the exhaust air
1
Recirculation mode units with internal remote fan
unit AR 400 743:
unit AR 400 743:
Attach the exhaust air pipe directly
to the fan motor's air pipe connector
(A)
.
2
Extraction mode units with internal remote fan unit
AR 400 743:
AR 400 743:
Attach the exhaust air pipe directly to
the fan motor's air pipe connector
(A)
.
$5
$
%
$5
$
%