Zephyr ZGEE30AS290 オーナーマニュアル

ページ / 49
Installation – 
Installing the Hood
6
www.zephyronline.com
DUCTING
A minimum of 6” round ducting must be used to 
maintain maximum air f ow eff ciency.
Always use rigid type metal ducts only. Flexible 
ducts could restrict air f ow by up to 50%.
Use calculation worksheet to compute total duct 
work.
ALWAYS, when possible, reduce the number of 
transitions and turns. If a long duct run is required, 
increase duct size from 6” to 7” or 8”.
If turns or transitions are required: Install as far 
away from opening and as far apart, between 2, 
as possible.
36”
24” min.
32” max.
Mounting height from top of cooking surface to 
bottom of hood should be no less than 24” and no 
more than 32”.
It is important to install the hood at the proper 
mounting height. Hoods mounted too low could 
result in heat damage and f re hazard while hoods 
mounted too high will be hard to reach and will 
lose performance and eff ciency.
If available, also refer to range manufacturer’s 
height clearance requirements and recommended 
hood mounting height above range. Always check 
your local codes for any differences.
DAMAGE-SHIPMENT / INSTALLATION:
•  Please fully inspect unit for damage before 
installation.
•  If the unit is damaged in shipment, return the 
unit to the store in which it was bought for 
repair or replacement.
•  If the unit is damaged by the customer, repair 
or replacement is the responsibility of the 
customer.
•  If the unit is damaged by the installer (if other 
than the customer), repair of replacement must 
be made by arrangement between customer 
and installer.