20" (50.8 cm) Freestanding Gas Range
PRODUCT MODEL NUMBERS
PRODUCT DIMENSIONS
CABINET OPENING DIMENSIONS
AGG222VD
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Electrical Requirements:
● 
A 120 volt, 60 Hz., AC only, 15-amp fused, electrical circuit is required. A time-delay
fuse or circuit breaker is also recommended. It is recommended that a separate circuit
serving only this range be provided.
● 
This range is equipped with a power supply cord having a 3 prong ground plug. To
minimize possible shock hazard, the cord must be plugged into a grounded 3 prong
outlet.
● 
Electronic ignition systems operate within wide voltage limits, but proper grounding
and polarity are necessary. Check that the outlet provides 120-volt power and is
correctly grounded.
This range is equipped with an electronic ignition system that will not operate if
plugged into an outlet that is not properly polarized.
Gas Supply Requirements:
Natural gas:
This range is design-certified by CSA International for use with Natural gas or, after
proper conversion, for use with LP gas.
● 
This range is factory set for use with Natural gas. See “Gas Conversions” section. The
model/serial rating plate located on the oven frame behind the left side of the broiler
door has information on the types of gas that can be used. If the types of gas listed do
not include the type of gas available, check with the local gas supplier.
LP gas conversion:
Conversion must be done by a qualified service technician.
No attempt shall be made to convert the appliance from the gas specified on the
model/serial rating plate for use with a different gas without consulting the serving gas
supplier. See “Gas Conversions” section.
Gas Supply Line
● 
Provide a gas supply line of 
³⁄₄" (1.9 cm) rigid pipe to the range location. A smaller size
pipe on longer runs may result in insufficient gas supply. With LP gas, piping or tubing
size can be 
¹⁄₂" (1.3 cm) minimum. Usually, LP gas suppliers determine the size and
materials used in the system.
NOTE:
Pipe-joint compounds that resist the action of LP gas must be used. Do not
use TEFLON
®†
tape.
Flexible metal appliance connector:
● 
If local codes permit, a new CSA design-certified, 4-5 ft (122-152.4 cm) long, 
¹⁄₂" 
(1.3 cm) or 
³⁄₄" (1.9 cm) I.D., flexible metal appliance connector may be used for
connecting range to the gas supply line.
● 
¹⁄₂" (1.3 cm) male pipe thread is needed for connection to the female pipe threads of
the inlet to the appliance pressure regulator.
● 
Do not kink or damage the flexible metal tubing when moving the range.
Rigid pipe connection:
The rigid pipe connection requires a combination of pipe fittings to obtain an in-line
connection to the range. The rigid pipe must be level with the range connection. All
strains must be removed from the supply and fuel lines so range will be level and in line.
● 
Must include a shutoff valve:
The supply line must be equipped with a manual shutoff valve. This valve should be
located in the same room but external to the range opening, such as an adjacent
cabinet. It should be in a location that allows ease of opening and closing. Do not block
access to shutoff valve. The valve is for turning on or shutting off gas to the range.
Ref. W10459123B
3/19/13
(65.9 cm)
(50 cm)
(106.6 cm)
For minimum
clearance to
top of cooktop,
see NOTE.
This shaded area
recommended for
installation
of gas pipe.
This shaded area
recommended for
electrical outlet.
18" (45.7 cm)
min. clearance
upper side
cabinet to
countertop
13" (33.0 cm) max.
upper cabinet depth
opening width
20" (50.8 cm) min. 
cabinet opening width
(14 cm)
2"
(5.1 cm)
(6.4 cm)
4"
(10 cm)
4"
(10 cm)
10" (25.4 cm)
3" (7.6 cm) min. 
countertop space to
side wall or other
combustible material
24"
(61.0 cm)
NOTE: 
24" (61 cm) minimum when bottom of wood or metal cabinet
is covered by not less than 
¹⁄₄" (0.64 cm) flame retardant millboard
covered with not less than No. 28 MSG sheet steel, 0.015" (0.4 mm)
stainless steel, 0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper.
30" (76.2 cm) minimum clearance between the top of the cooking
platform and the bottom of an uncovered wood or metal cabinet.
IMPORTANT:
If installing a range hood or microwave hood
combination above the range, follow the range hood or microwave
hood combination installation instructions for dimensional clearances
above the cooktop surface.