If the cable from appliance is equipped with 4 wires:
Where local codes permit connecting the 
appliance-grounding conductor (wire) to the 
neutral (white) wire (see fi gure 5): 
1.  Disconnect the power supply.
2.  In the circuit breaker, fuse box or junction box, 
connect appliance and power supply cable wires 
as shown in fi gure 5.
 This appliance is manufactured 
with a white neutral power supply and a frame 
connected copper wire. The frame is grounded by 
connection of grounding lead to neutral lead at 
the termination of the conduit, if used in USA, in a 
new branch circuit installation (1996 NEC), mobile 
home, recreational vehicles, where local code do 
not permit grounding trough the neutral (white) 
wire or in Canada, disconnect the white and 
green lead from each other and use ground lead 
to ground unit in accordance with local codes, 
connect neutral lead to branch circuit-neutral 
conductor in usual manner see Figure 6. If your 
appliance is to be connected to a 3 wire grounded 
junction box (US only), where local code permit 
connecting the appliance-grounding conductor to 
the neutral (white) see Figure 5.
Figure 5
3-WIRE GROUNDED JUNCTION BOX
Cable from Power Supply
Junction 
Box
Cable from appliance
U.L.-Listed Conduit 
Connector (or CSA listed)
Red
Wires
White Wire
(Neutral)
Black 
Wires
Ground Wire
(Bare or Green Wire)
White Wire
(Neutral)
If cooktop is used in a new branch circuit 
installation (1996 NEC), mobile home, recreational 
vehicle, or where local codes DO NOT permit 
grounding through the neutral (white) wire (see 
fi gure 6):
 
1.  Disconnect the power supply.
2.  Separate the green (or bare copper) and white 
appliance cable wires.
3. In the circuit breaker, fuse box or junction box:
 
connect appliance and power supply cable wires 
as shown in fi gure 6.
Figure 6
4-WIRE GROUNDED JUNCTION BOX
Cable from Power Supply
Junction Box
Cable from appliance
Ground
Wire
U.L.-Listed Conduit 
Connector (or CSA listed)
WARNING
 If connecting to a 4-wire power 
supply cable electrical system, the appliance 
frame connected ground wire MUST NOT be 
connected to the neutral wire of the 4-wire 
electrical system.
NOTE TO  ELECTRICIAN: The armored cable 
leads supplied with the appliance are UL and 
CSA-recognized for connection to larger gauge 
household wiring. The insulation of the leads is rated 
at temperatures much higher than temperature rating 
of household wiring. The current carrying capacity of 
the conductor is governed by the temperature rating 
of the insulation around the wire, rather than the wire 
gauge alone.
Red
Wires
White
Wires
Black 
Wires
Ground Wire
(Bare or