INTERNAL BLOWER PREPARATION CONT. 
7.  Secure motor housing to hood body by (12) M4*6 
screws.
8.  Connect 6 pin molex connector from capacitor 
cable to 6 pin molex connector from control box. 
Connect 2 pin plug from AC power cable to 2 pin 
plug from control box. Secure cables to hood 
interior with zip ties and zip tie holders.
1.  Remove internal blower fl ange from motor 
housing by (6) screws.
2.  Secure AC power box and remove blower 
wiring box to remote blower fl ange by (2) M4*8 
screws each. 
Installation – 
Blower Preparation
REMOTE BLOWER PREPARATION
9.  Secure capacitor box to internal hood body by 
(2) M4*8 screws and secure ground wire by (1) 
3/16*3/8 screws.