WALL
OKEANITO
*Mounting height refers to distance between top of a 36” tall cooking surface and bottom of hood.
Specifications subject to change, check zephyronline.com for up to date information.
* 10” round duct connects to external and in-line blower. Must transition from 10” to 8” before duct passes 
through ceiling. A 10” to 8” adapter is included with the external and in-line blowers.   
** AC power listed above is for hood with lights only. For blower specifications please refer to the blower spec sheet.
36”, 42”, 48”
10”
14-1/2”
Front
14
-1/2”
  
22
-3/4”  
13
-1/2”
 
Standard Duct Cover
min: 30-1/2”
max: 49-1/2”
Z1C-00OK Extension
min: 44”
max: 77”
Side
Top
10”
6”
duct cover
C/L
4-1/4”
6” collar C/L
duct cover
5-1/8”
8” collar C/L
MODEL
COK-E36BSX
COK-E42BSX
COK-E48BSX
  
 
 
 
36”
 42”
 48”
PERFORM A NCE*
Internal Blower - CBI-290A
 
200 - 290 CFM, 1.4 - 3.2 Sones
Internal Blower - CBI-600A  240 - 600 CFM, 1.8 - 6 Sones
In-Line Blower - PBN-1000A  500 - 1000 CFM, Sones NA
External Blower - CBE-1000  500 - 1000 CFM, Sones NA
COLOR
 Stainless Steel
FE ATURE S
Controls  Electronic Touch
Speed Levels
 
3
Auto Delay-Off
 
Yes
Lighting
COK-E36BSX, COK-E42BSX  Bloom™ HD LED, 6W (2)
COK-E36BSX, COK-E42BSX  Incandescent, 40W (2)
COK-E48BSX  Bloom™ HD LED, 6W (4)
COK-E48BSX  Incandescent, 40W (4)
Dual-Level Lighting  Yes, Bloom™ HD LED
Filters  Professional Baffle
Recirculating
 
No
Duct Cover Extension  Yes, Up to 12’ Ceiling
DUC T SPECIFICATIONS
Vertical - Internal  6”
Vertical - External / In-Line  10” - 8”*
Horizontal
 
NA
AC INPUT
 120V - 60Hz
AC POW ER**
COK-E36BSX, COK-E42BSX  Max. 80 Watts, 0.55 Amps
COK-E48BSX  Max. 92 Watts, 0.65 Amps
OP TION A L ACCE SSORIE S
Duct Cover Extension Kit  Z1C-00OK
Wireless Remote Control
 
14000005
MOUNTING HEIGHT
 26” - 36”
WA RR A NT Y
 3 Years Parts, 1 Year Labor
CEILING HEIGHT
8’
8.5’
9’
9.5’
10’
10.5’
11’
12’
STANDARD DUCT COVER MOUNTING HEIGHT*
26”-30”
26”-36”
26”-36”
26”-36”
32”-36”
NA
NA
NA
EXTENSION DUCT COVER MOUNTING HEIGHT*
NA
NA
26”-28”
26”-34”
26”-36”
26”-36”
26”-36”
30”-36”
* Requires purchase of Zephyr blower, sold separately.