5
INSTALLATION REQUIREMENTS
Water supply requirements
Hot and cold water faucets MUST be installed within 42 
inches (107 cm) of your washer’s water inlet. The faucets 
MUST be 3/4 inch (1.9 cm) with threading for laundry 
hose connection. Water pressure MUST be between 
10 psi (0.69 bars) and 120 psi (8.27 bars). Pressure 
difference between hot and cold cannot be more than 10 
psi. Your water department can advise you of your water 
pressure.
WARNING
EXPLOSION HAZARD
Uncoated copper tubing will corrode when subjected 
to natural gas, causing gas leaks. Use ONLY black iron, 
stainless steel, or plastic-coated brass piping for gas 
supply.
Gas supply requirements
Electrical requirements for Laundry Center with gas dryer
CIRCUIT -  Individual, properly polarized and grounded 
15 amp. branch circuit fused with 15 amp. time delay 
fuse or circuit breaker.
POWER SUPPLY - 2-wire, with ground, 120 volt, single 
phase, 60 Hz, Alternating Current. 
POWER SUPPLY CORD - The dryer is equipped with a 120 
volt 3-wire power cord. 
GROUNDING CONNECTION - See “Grounding 
requirements” in Electrical Installation section. 
Grounding type
Grounding type
wa
wall receptacl
ll receptacle
Po
Power cord with
wer cord with
3-prong 
3-prong  gr
grounded plug
ounded plug
Do not,
Do not, under
under
an
any cir
y circumstances,
cumstances,
cut,
cut, remo
remove
ve,
or b
or bypass th
ypass the
gr
grounding pr
ounding prong.
ong.
1  Installation MUST conform with local codes, or in 
the absence of local codes, with the National Fuel 
Gas Code, ANSI Z223.1 (latest edition). 
2  The gas supply line should be 1/2 inch (1.27 cm) 
pipe. 
3  If codes allow, fl exible metal tubing may be used 
to connect your dryer to the gas supply line. The 
tubing MUST be constructed of stainless steel or 
plastic-coated brass.
  4  The gas supply line MUST have an individual 
shutoff valve installed in accordance with the 
B149.1, Natural Gas and Propane Installation Code.
  5  A 1/8 inch (0.32 cm) N.P.T. plugged tapping, 
accessible for test gauge connection, MUST be 
installed immediately upstream of the gas supply 
connection to the dryer.
  6  The dryer MUST be disconnected from the gas 
supply piping system during any pressure testing 
of the gas supply piping system at test pressures in 
excess of 1/2 psig (3.45 kPa).
  7  The dryer MUST be isolated from the gas supply 
piping system during any pressure testing of the 
gas supply piping system at test pressures equal to 
or less than 1/2 psig (3.45 kPa).
  8  Connections for the gas supply must comply with 
the Standard for Connectors for Gas Appliances, 
ANSI Z21.24.
NOTE
Washers connected to water supplies with lower inlet 
pressure will experience longer fi lling times and may 
not complete cycles as quickly.