4  Error Messages and Beep Codes 
What This Chapter Contains 
4.1
 
BIOS Error Messages .................................................................................................. 97
 
4.2
 
Port 80h POST Codes ................................................................................................. 99
 
4.3
 
Bus Initialization Checkpoints .................................................................................... 103
 
4.4
 
Speaker ..................................................................................................................... 104
 
4.5
 
BIOS Beep Codes...................................................................................................... 104
 
4.1  BIOS Error Messages 
Table 49 lists the error messages and provides a brief description of each. 
Table 49.  BIOS Error Messages 
Error Message 
Explanation 
GA20 Error 
An error occurred with Gate A20 when switching to protected 
mode during the memory test.  
Pri Master HDD Error  
Pri Slave HDD Error 
Could not read sector from corresponding drive. 
Pri Master Drive - ATAPI Incompatible 
Pri Slave Drive - ATAPI Incompatible 
Corresponding drive in not an ATAPI device.  Run Setup to make 
sure device is selected correctly. 
A:  Drive Error 
No response from diskette drive. 
Cache Memory Bad 
An error occurred when testing L2 cache.  Cache memory may be 
bad. 
CMOS Battery Low 
The battery may be losing power.  Replace the battery soon. 
CMOS Display Type Wrong 
The display type is different than what has been stored in CMOS.  
Check Setup to make sure type is correct. 
CMOS Checksum Bad 
The CMOS checksum is incorrect.  CMOS memory may have 
been corrupted.  Run Setup to reset values. 
CMOS Settings Wrong 
CMOS values are not the same as the last boot.  These values 
have either been corrupted or the battery has failed. 
CMOS Date/Time Not Set 
The time and/or date values stored in CMOS are invalid.  Run 
Setup to set correct values. 
DMA Error 
Error during read/write test of DMA controller. 
FDC Failure 
Error occurred trying to access diskette drive controller. 
HDC Failure 
Error occurred trying to access hard disk controller. 
Checking NVRAM..... 
NVRAM is being checked to see if it is valid. 
continued 
 97