* If a rectangular-to-round transition adapter is used, first 
make sure the damper hinge of the microwave swings 
freely. If necessary, cut the damper to fit, using the tin 
snips, in order to allow free movement.
Equivalent lengths of duct pieces are based on actual 
tests and reflect requirements for good venting 
performance with any vent hood.
Testing Operation
1.
Turn on power at the breaker.
2.
Test the microwave:
Place a cup of water into the oven cavity. Follow the 
instructions in the Use and Care Manual on how to 
heat a beverage.
3.
Verify that the oven light comes on and the water is 
heated.
4.
If any of the tests do not result as explained above, 
contact service for assistance. Otherwise, the 
installation is complete at this time.
45° Elbow
5 ft (1.5 m)
x
=
90° Elbow
25 ft (7.6 m)
x
=
45° Elbow
5 ft (1.5 m)
x
=
Roof Cap
24 ft (7.3 m)
x
=
Straight Duct 6" (152 mm 
Round or 3 1/4" x 10" 
(82 x 254 mm) Rectangular
1 ft (0.3 m)
x
=
Duct Pieces
x
Number used
=
Equivalent Length
Total Ductwork =