Fujitsu PRIMERGY RX200 S5 VFY:R2005SF010NL プリント

製品コード
VFY:R2005SF010NL
ページ / 2
Form Factor
Available Processor Sockets
Available DIMM Slots / Max Memory Capacity
ECC and/or Fully Buffered DIMMs
Available Expansion Slots
Minimum and Maximum # of Hard Drives
Redundant Power Supply Capable?
Power Supply Make and Model
Delta Electronics, DPS-770BB A
Power Supply Output Rating
*
 (watts)
Minimum and Maximum # of Power Supplies
Input Power Range (AC or DC)
Power Supply Efficiency at Specified Loadings
*
Power Supply Power Factor at Specified Loadings
*
Operating Systems Supported
Installed Operating System for Testing
Processor Information
1U Rackmount
2
12 / 96GB
MS Windows Server 2008 Enterprise Edition, SP2
100 - 240V AC
PRIMERGY RX200 S5; LKN:R2005S0010IN
ENERGY STAR
®
 Power and Performance Data Sheet
75.6%@10%, 85.2%@20%, 89.4%@50%, 89.4%@100%
0.927@10%, 0.969@20%, 0.995@50%, 0.998@100%
System Characteristics
1 and 2
ECC and registered DIMMs
 System Configurations
2 x Intel® Xeon® X5550 (4 cores, 2.66GHz)
3  PCIe
Microsoft® Windows Server® 2008
Microsoft® Windows Server® 2003
Novell SUSE Linux Enterprise Server
Red Hat Enterprise Linux
Citrix® XenServer™
VMware Infrastructure
VMware vSphere 4.0
Note: Power supply information is for a single power supply only 
0 and 8
Yes
770W
Processor Information
Memory Information 
Internal Storage
I/O Devices
Power Supply Number and Redundancy Configuration
Management Controller or Service Processor Installed?
Other Hardware Features / Accessories
Idle Category  (1S and 2S only)
ENERGY STAR Idle Power Allowance (1S and 2S only)
Measured Idle Power (watts)
Power at Full Load
*
 (watts)
Benchmark / Method Used for Full Load Test
Test Voltage and Frequency for Idle and Full Load Test
Range of Total Estimated Energy Usage 
**
 (kWh/year)
Link to Detailed Power Calculator (if available)  
2 x 2.5" SAS HDD, 2 x 73GB, 2 x 10000 RPM
** 
Note: Estimated kWh/year gives the absolute range of energy use a user could expect from continuous operation (24x365) and ranges from 100% Idle usage to 100% full 
load operation.  The calculation also includes typical data center overhead at a ratio of 1 watt of overhead to every 1 watt of IT load (corresponding to a PUE of 2.0). Closer 
approximations may be found by using established power calculators and specific information about the intended operating environment (e.g., average time at Idle, data 
center PUE, etc.).
230V / 50Hz
SiSoftware Sandra Engineer 2009.SP3c, .Net Multimedia, Double x1
2836 to 5421
Note: Full load power represents the sustained, average power at 100% load of the given workload, and does not necessarily represent the absolute peak power or the 
highest average, sustained power possible for other workloads. 
2 x Intel® Xeon® X5550 (4 cores, 2.66GHz)
12GB (6 x 2GB), PC3-10600R DDR3-1333 reg ECC
161,9
309,4
Category D: Managed Dual Installed Processor (2P) Servers
Power Data
1 x Intel® 82575EB Dual Port Gigabit Server Adapter
2 installed, (1 redundant)
Yes
8 port SAS RAID Controller with LSI 1068 in PCIe slot
DVD-RW supermulti
194W