Before You Call for Service
Problem Solution Guide
Problem
May be caused by
What to do
Nothing works. Appliance does 
not cool, control panel display is 
off and light does not work.
Appliance not connected to 
electrical power.
Make sure appliance is plugged in.
Electricity to power outlet is off.
Turn power on at the circuit breaker panel or fuse box. 
Check for tripped circuit breaker or blown fuse.
Appliance is turned off.
See Turning the Power On and Off on page 4.
Compressor reset delay.
The unit has a compressor reset delay circuit designed 
to protect the compressor when it is warm. When the 
compressor is warm, the reset delay prevents the unit 
from restarting for 3 to 5 minutes. If the unit will not 
start, disconnect the power cord for 5 minutes, then 
reconnect.
Power outage.
Contact power company.
Light does not come on.
No power.
See Nothing works above.
Light is turned off.
See Interior Lighting on page 4.
Light malfunctioning.
Call for service to have it replaced. See Getting Help.
Unusual noises.
Bottles vibrating.
Adjust bottles and racks to minimize vibration.
Appliance not standing firmly on 
floor.
Check appliance leveling according to Installation 
section. If problem persists, contact installer. Have 
installer level appliance or modify installation.
Object(s) have fallen behind the 
unit and are causing vibration. 
Pull unit out and check for objects that have fallen 
behind it.
Appliance runs constantly.
Room temperature too hot.
Make sure room temperature is not too hot. See 
Operating Temperature Requirements on page 7. 
Adjust ventilation system if necessary.
Door has been left ajar or opened 
too often.
Make sure door is firmly shut. Do not open the door 
unless necessary.
Appliance mounted too close to 
heat source.
Have a technician or installer modify the appliance 
installation or the heat source.
A lot of bottles added to appliance. The appliance will run until it has had a chance to cool 
all the bottles.
Temperature not cold enough.
Temperature not set properly. 
See Setting the Temperature on page 4.
A lot of bottles added to appliance 
or appliance just turned on.
Appliance will run until it has had a chance to cool all 
the bottles.
Door opened too often or left open. Leave door closed to allow unit to cool inside.
Ambient room temperature too 
high
The operating temperature for this appliance is 60°F 
(16°C) to 90°F (32°C).
Poor air flow around wine cellar.
Check to make sure that adequate room for air flow 
has been provided on the sides, top and back. See 
Installation section on page 7. 
Vents dirty or blocked.
Clean vents on front and back of appliance.
See Appliance runs constantly
above.
Condensation on outside 
surfaces of glass door.
High humidity climate.
During periods of high humidity, some condensation 
may appear on outside surfaces of glass door. It will 
disappear when humidity levels drop. It is advisable to 
install the appliance with sufficient ventilation in a dry 
and/or an air-conditioned place.
Door will not open.
Door locked.
See page 3.