Zephyr ZRVE30AGC オーナーマニュアル

ページ / 44
9
1.  Measure from range top to hood bottom and mark line A.  (26” 
minimum from range top) .
2.  Plum and mark center line.
3.  Mark mounting height line B. (15 7/8” from line A)
4.  Mark mounting spread from C/L. (8 15/16”) 
5.  Fasten (2) M6 x 1-1/2” screws into studs on line B but do not 
tighten all the way.  Note: Wood blocking may need to be 
added behind the drywall if no studs are present.  Wall 
anchors may also be used but check local codes for 
compliance. Failure to use suitable wall anchors and 
screws to hold the weight of the hood could result in 
personal injury or damage to cooking surface or counter.
6.    Remove (2) screws securing electrical junction box to motor 
housing. Remove junction box.
8.  Remove the (1) aluminum mesh fi lter.
9.  Hang hood onto the mounting screws and hand tighten each 
screw. (FIG. A #1) Secure third M6 x 1-1/2” screw through inside 
of hood into wall for extra support. (FIG. A #2) 
10.  Center and attach duct cover mounting bracket to wall just 
below the ceiling or soffi t using (2) M6 x 1” screws.
11.  Install electrical and duct work.  Seal duct work with aluminum 
duct tape. Re-install electrical junction box with cable lock and 
install the electrical. (FIG. B #2)
12.  Power up hood and check for leaks around duct tape.
13.  Place telescopic duct covers onto hood and extend inner (top) 
duct cover upwards and secure to duct cover bracket using (2) 
M3.5 x 8 screws. 
14.  Place canopy over hood body and secure it to hood body using 
(4) 3/16 x 1/4 screws through fi lter opening. 
15.  Reinstall aluminum mesh fi lter.
* If using hood in recirculating mode you must secure the air diverter 
plate onto wall before installing duct work and duct covers.  Turn 
to page 10 for more details.
8 15/16”
15 7/8”
Brackets are 
pre-installed
2
26” min
1
CAUTION: At least two installers are
required due to the weight and size of the
hood.
!
WARNING: Electrical wiring must be done by a qualified person(s) in
accordance with all applicable codes and standards. This range hood must be
properly grounded. Turn off electrical power at service entrance before wiring.
!
Installation – 
Mounting the Hood
Cable Lock
Cable Lock
A cable locking connector (not supplied) might 
be required by local codes.  Check with local 
requirements and codes, purchase and install 
appropriate connector if necessary.
FIG. A