Electrolux EIMED60L 図

ページ / 12
2
Error
Code
E71
E72
E73
E74
E91
E92
E93
E94
E97
EA1
EA2
EA3
EA4
EA5
EF1
EF3
EF8
Fault
Outlet Control
Thermistor open
circuit
Outlet Control
Thermistor short
circuit
Inlet Control
Thermistor open
circuit
Inlet Control
Thermistor short
circuit
Communication
Error
Incompatible
protocol
Machine
configuration
checksum error
Cycle configuration
checksum error
Program mismatch
Main Supply
Frequency out of
Range
Voltage too high
Voltage too low
Improper home
wiring
Main V Sensing
failure
Vent Blocked
Max Timeout Timer
Key Stuck
Possible Fault Conditions
Outlet Control Thermistor or wiring
defective
Outlet Control Thermistor or wiring
defective
Inlet Control Thermistor or wiring
defective
Inlet Control Thermistor or wiring
defective
Wiring, Electronic Control Board, or
Interface Board defective
Electronic Control Board incompatible
with Interface Board
Wrong configuration data loaded,
Interface Board or Electronic Control
Board or wiring defective
Wrong configuration data loaded or
Electronic Control Board defective
Wrong configuration data loaded,
Electronic Control Board defective
Line frequency out of limits or
Electronic Control Board faulty
Line voltage too high or Electronic
Control Board faulty
Line voltage too low or Electronic
Control Board faulty
Line connections in home faulty,
wiring or Electronic Control Board
defective
Electronic Control Board defective
High vent restriction, Exhaust Control
Thermistor, Inlet Control Thermistor, or
Electronic Control Board defective
Exhaust blocked;  Exhaust Control
Thermistor, Inlet Control
Thermistor, Contact Sensor or
Electronic Control Board defective
Console button or Interface Board
defective
Possible Solutions
Check resistance of Outlet Control Thermistor, and check wiring for open circuit.
Resistance should be between 4.9K Ohm and 6.2K Ohm at room temperature
(68-77° F or 20-25° C).  Replace Outlet Control Thermistor and/or wiring and
retest.
Check resistance of Outlet Control Thermistor, and check wiring for short circuit
across Thermistor connections.  Resistance should be between 4.9K Ohm and
6.2K Ohm at room temperature (68-77° F or 20-25° C).  Replace Outlet Control
Thermistor and/or wiring and retest.
Check resistance of Inlet Control Thermistor, and check wiring for open circuit.
Resistance should be between 47K Ohm and 66K Ohm at room temperature
(68-77° F or 20-25° C).  Replace Inlet Control Thermistor and/or wiring and
retest.
Check resistance of Inlet Control Thermistor, and check wiring for short circuit
across Thermistor connections.  Resistance should be between 47K Ohm and
66K Ohm at room temperature (68-77° F or 20-25° C).  Replace Inlet Control
Thermistor and/or wiring and retest.
Check connections between Electronic Control Board and Interface Board. If no
wiring problems, replace Electronic Control Board or Interface Board.
Check if correct Interface Board console and Electronic Control Board are
installed. Replace appropriate hardware.
Check if correct Interface Board and console are installed. Replace Interface
Board and/or console.
Replace Electronic Control Board.
Replace Electronic Control Board.
Check frequency of line voltage.
Check amplitude of line voltage.
Check amplitude of line voltage.
Check wiring at terminal block for L1-N-L2 wired incorrectly.
Replace Electronic Control Board.
Check vent restrictions and resistance values of Exhaust Control Thermistor
and Inlet Control Thermistor.
Check vent restriction, Contact Sensor, and resistance values of Exhaust
Control Thermistor and Inlet Control Thermistor
Check buttons for activation when pressed. Replace console or Interface Board
as appropriate
FACTORY RESET
1.  Press and hold the “Temperature” and “Dryness” buttons simultaneously for 6 seconds.
INSTALLATION CYCLE
1.  Use the selector knob to select the “touch up” cycle
2.  Press and hold the “my favorite” and “sanitize” buttons simultaneously for 6 seconds.
3.  Remove any load from the dryer and press “start pause” to start installation cycle.
DIAGNOSTIC MODE
1.
Press the “cancel” button to enter standby mode and enable diagnostic entry.
2.
Within 10 seconds after pressing “cancel”, press any button (but “cancel”) to wake up the control.
3.
Within 5 seconds of wake up, turn the selector knob to the far left cycle and press and hold the “cancel” and the far left
button under the display
 simultaneously for 3 seconds to enter the Diagnostic Mode.  (note: to save time at wake up,
the welcome screen can be bypassed by turning the selector knob).
4.   Upon entering Diagnostic Mode, all lights should flash on and off.
5.
The following steps can be cycled through by turning the selector knob clockwise: