Wolf GR606DGLP インストールガイド

ページ / 12
10   
|
   Wolf Customer Care 800.222.7820
Troubleshooting
IMPORTANT NOTE:
 If the range does not operate properly, 
follow these troubleshooting steps:
    Verify electrical power is supplied to the range.
    Verify the gas supply shut-off valve is in the open 
position.
    If the range does not operate properly, contact Wolf 
factory certified service. Do not attempt to repair the 
range. Wolf is not responsible for service required to 
correct a faulty installation.
INSTALLATION
Gas Supply Connection
All connections to the gas piping must be wrench-tightened. 
Do not overtighten or allow pipes to turn when tightening.
If a flexible metal connector is being used, verify it is not 
kinked, then attach the gas supply line to the regulator on 
the range. Open the valve and check for leaks by placing a 
liquid detergent solution onto all gas connections. Bubbles 
around connections indicate a gas leak. If a leak appears, 
close the shut-off valve and adjust connections.