www.zephyronline.com
Maintenance – 
Self Cleaning
SELF CLEAING FEATURE
Zephyr Typhoon, Hurricane and Cyclone hoods are filter-less with a self cleaning feature.  The 
centrifugal blower system automatically liquifies cooking residue in its internal housing.  All hoods 
are equipped with dishwasher safe residue cups to collect cooking residue during the self cleaning 
function.
Cooking residues are often automatically liquified and can accumulate in the residue cups from
everyday use.  Nevertheless, grease from cooking could also dry and adhere to the internal housing.
Running the self clean function periodically will flush out accumulated residue in the range hood’s
internal housing.
CLEANING FREQUENCY
Cleaning should be performed approximately once a month under normal usage of 1 hour per day.  
The hood may need to be cleaned more often if you cook heavily.
DETERGENT
Use a grease cutting detergent such as Simple Green or 409.
WARNING
Use extreme caution while cleaning the hood.  Beware of blowers catching 
on to hair, loose clothing and fingers. NEVER leave children unattended.
1) Power on blowers at Speed 1 
2) With nozzle on “spray”, squirt grease cutting 
detergent onto blower wheel blades 30 - 35 times.  
Repeat for each blower. Leave blower on for 10 
minutes. Detergent will collect in the residue cups.
3) Remove residue cups.  Clean residue cups and 
in dishwaser or clean by hand. Install residue cups 
after cleaning.
CLEANING INSTRUCTIONS
Q     2     3
1
AK21
AK25
AK65
1
2
0
3