Mounting the Hood
All Electrical work must by performed by qualified 
electrician or person with similar technical know how 
and background.
For personal safety, remove house fuse or open circuit
breaker before beginning installation.
Do not use extension cord or adapter plug with 
this appliance. 
Follow National electrical codes or prevailing local
codes and ordinances.
Electrical Supply:
This appliance requires a 120V 60Hz electrical supply.,
and connected to an individual, properly grounded branch 
circuit, protected by a 15 or 20 ampere circuit breaker or
time delay fuse. Wiring must be 2 wire w/ ground. Please
refer to Electrical Diagram labeled on product. 
ELECTRICAL - WARNING
1. Temporarely position the hood in the
desired mounting location. Measure and
mark the mounting holes, duct and electri-
cal access locations with a pencil. Remove
hood and drill/cut out the requirred open-
ings for duct and electrical access.
3. Hang hood from mounting screws 
provided. Slide hood toward wall until
mounting screws are engaged in narrow
end of keyholes. Tighten mounting screws
securely. CAUTION: Do not push on safety
grill when installing, this may result in 
damage to the motor.
2. Attach house electrical wiring to 
hood wiring. Make sure the power source 
is turned off before working with any 
electrical wiring.
4. Attach duct work. Use aluminum duct
tape to make joints secure and air tight. 
NOTE: This step is not necessary if hood is
in air recirculation mode.
5. If not already done, install light bulbs by
screwing in clockwise.