Wolf IF15S インストール手順

ページ / 12
Steamer Module Specifications
4
7
1
/
2
"
(191)
1
/
2
"
(13)
SIDES
1"
(25)
FRONT / BACK
6"
(152)
DRAIN
OUTLET
21"
(533)
15"
(381)
Overall Dimensions
STEAMER MODULE
Installation Specifications
IMPORTANT NOTE:
Installation of the Wolf electric
steamer module must meet minimum clearance require-
ments shown in the installation illustration on page 6.
The Wolf steamer module is intended for indoor use. It is
designed to fit a standard 24"
(610)
deep base cabinet with
25"
(635)
deep countertop. Before making the countertop
cut-out, verify that the module will clear the side walls of
the base cabinet.
It is recommended that you use a Wolf cooktop ventilation
hood, pro hood or hood liner with the steamer module.
Refer to the Wolf design guide.
IMPORTANT NOTE:
Wolf does not recommend the use of
downdraft ventilation with the steamer module.
DRAIN CONNECTION
IMPORTANT NOTE:
It is recommended that the steamer
module be installed with a drain connection and access to
the drain through the base cabinet.
The
5
/
8
"
(16)
outlet from the steamer module valve will
accept a drain hose that must flow downward to, and tie
into, an existing sink drain. A separate drain with a freefall
may also be installed. If you do not have a fixed drain
connection, a heat-resistant bucket can be positioned
under the drain outlet to accept the water. The bucket
must have a minimum 2 gallon
(7.6 L)
capacity. Refer to the
installation illustration on page 6 for location of the drain
outlet.
Failure to locate the steamer module without the
proper clearances will result in a fire hazard.