Maytag MEDB855D インストール手順

ページ / 44
15
1.
 
Prepare to connect neutral 
     ground wire and neutral wire
B
A
E
Remove center terminal block screw (B). Remove neutral 
ground wire (E) from external ground conductor screw (A).
Optional 3-wire Connection
You must verify with a qualified  electrician that this grounding 
method is acceptable before connecting.
B
E
C
Connect neutral ground wire 
and neutral wire
2. 
Connect neutral ground wire (E) and neutral wire (white or 
center wire) (C) of power supply cord or cable under center 
terminal block screw (B). Tighten screw.
Connect remaining wires
3.
Place hooked ends of remaining wires under outer terminal 
block screws (hooks facing right). Tighten screws. 
A
G
Connect external ground wire
4.
Connect a separate copper ground wire (G) from the external 
ground conductor screw (A) to an adequate ground. Finally, 
reinsert tab of terminal block cover into slot of dryer rear 
panel. Secure cover with hold-down screw. Now, go to 
“Venting Requirements.”