Electrolux EI30GF45QS インストール手順

ページ / 32
7
30" GAS RANGE INSTALLATION INSTRUCTIONS
Figure 5b
Figure 5c
4
 Connect the range to the gas supply
Important: Remove all packing material and literature 
from range before connecting gas and electrical supply.
Note: To prevent leaks, put pipe joint sealant on all 
external pipe threads.
 Do not allow regulator to rotate on 
pipe when tightening fi ttings.
Connection to Pressure Regulator
The regulator is already installed on the appliance.
 Do not make the connection too tight. 
The regulator is die cast. Overtightening may crack the 
regulator resulting in a gas leak and possible fi re or 
explosion.
Checking Manifold Gas Pressure
Disconnect this range and its individual manual shutoff 
valve from the gas supply piping system during any 
pressure testing of that system at test pressures greater 
than 14" water column pressure (approximately ½" psig).
The appliance must be isolated from the gas supply 
piping system by closing its individual manual shutoff 
valve during any pressure testing of the gas supply 
piping system at test pressures equal to or less than 
14" water column pressure (approximately ½" psig).
If it should be necessary to check the manifold gas 
pressure, connect manometer (water gauge) or 
other pressure device to the top burner right rear 
orifi ce. Using a rubber hose with inside diameter of 
approximately ¼" hold tubing down tight over orifi ce. 
Turn burner valve on.
For accurate pressure check have at least two (2) 
other top burners burning. Be sure the gas supply 
(inlet) pressure is at least one inch above specifi ed 
range manifold pressure. The gas supply pressure 
should never be over 14" water column. When properly 
adjusted for Natural Gas manifold pressure is 4" (For 
LP/Propane Gas the manifold pressure is 10")
Note: The purpose of forming the gas fl exible 
connector is to position it in a way that will not block 
the unit or get pinched in it's fi nal position.
If your unit in place is not against the wall as you 
wish, check behind the range and place the gas 
fl exible connector to avoid the range being blocked 
or the gas fl exible connector being pinched. 
A.  Install an external manual gas shut-off valve to gas 
supply line in an accessible location outside of the 
range. Be sure you know where and how to shut off 
the gas supply to the range.
B.  Install ½" fl are union adapter to unit shut-off valve 
using NO MORE THAN 15ft./lbs. of torque. 
 
NOTE: Be sure to stabilize the right side of the 
unit shut-off valve with adjustable wrench before 
tightening ANY fi ttings to the unit shut-off valve.
C.  Tighten the gas fl exible connector and/or appliance 
conduit to fl are union on the left side of the unit 
shut-off valve using NO MORE THAN 15ft./
lbs.
 of torque. Be sure to stabilize the ½" fl are 
union adapter with an adjustable wrench before 
tightening the gas fl exible connector and/or 
appliance conduit.
D.  Install fl are union adapter to external shut-off valve.
E.  Attach the gas fl exible connector with the fl are 
union on shut-off valve.
F.  Make sure both shut-off valves are in the "ON" 
position.
G.  Form the gas fl exible connector as shown on fi gure 
5c. This will prevent the fl exible connector from 
pinching or blocking the unit when you will push it 
back in its fi nal position.
H.  Check for leaks. Turn the gas supply on to the range 
and use a liquid leak detector (or soap and water) at 
all joints and conduits to check for leaks in the system.
 Do not use a fl ame to check for gas 
leaks.