Installation – 
Mounting Height & Clearance
6
www.zephyronline.com
DUCTING
A minimum of 10” round duct is recommended to 
PDLQWDLQPD[LPXPDLUÀRZHI¿FLHQF\
Always use rigid type metal ducts only. Flexible 
GXFWVFRXOGUHVWULFWDLUÀRZE\XSWR
Use calculation worksheet to compute total duct 
ZRUN 3DJH 
ALWAYS, when possible, reduce the number of 
transitions and turns. If a long duct run is required, 
increase duct size from 10” to 12”.
If turns or transitions are required: Install as far 
away from duct opening and as far apart between 
the two transitions as possible.
Minimum mount height between range top to hood 
bottom should be no less than 26”.
Maximum mount height should be no higher than 
34”.
It is important to install the hood at the proper 
mounting height. Hoods mounted too low could 
UHVXOWLQKHDWGDPDJHDQG¿UHKD]DUGZKLOHKRRGV
mounted too high will be hard to reach and will 
ORRVHSHUIRUPDQFHDQGHI¿FLHQF\
If available, also refer to range manufacturer’s 
height clearance requirements and recommended 
hood mounting height above range. Always check 
your local codes for any differences.
Duct cover extension kit available for ceiling 
heights up to 12 feet. Turn to page 16 for part 
number and ordering information.
DAMAGE-SHIPMENT / INSTALLATION:
‡ 3OHDVHIXOO\LQVSHFWXQLWIRUGDPDJHEHIRUH
installation.
‡ ,IWKHXQLWLVGDPDJHGLQVKLSPHQWUHWXUQWKH
unit to the store in which it was bought for 
repair or replacement.
‡ ,IWKHXQLWLVGDPDJHGE\WKHFXVWRPHUUHSDLU
or replacement is the responsibility of the 
customer.
‡ ,IWKHXQLWLVGDPDJHGE\WKHLQVWDOOHU LIRWKHU
WKDQWKHFXVWRPHU UHSDLURIUHSODFHPHQWPXVW
be made by arrangement between customer 
and installer.
min.  A
min.  B
max. C
    
 
 
 
Standard  
 Extension
Hood Heights  
 
Duct Cover 
 Duct Cove
r
            minimum ducted (A)  32 
1/2
”   
        49“
 minimum recirculating (B)  NA 
 
        NA
                          maximum (C)  48 
1/2
”   
        81”
Ceiling Heights
           minimum ducted (D)  94 
1/2
” (7’ 10 
1/2”)     
111“ (9’ 3”)
 minimum recirculating (E)  NA 
 
         NA
                          maximum (F)  118 
1/2
” (9’ 10 
1/2
“)  151” (12’ 7”)
36”
26” min.
34” max.
min.  D
min.  E
max. F