Friedrich DC2 インストール手順

ページ / 1
INSTALLATION INSTRUCTIONS
FOR DC-2 DRAIN KIT
STEP 1  Before sliding chassis into outer shell, turn chassis on its side and add drain hole by drilling 
½” diameter hole as shown in Figure 1.
STEP 2  DC-2 mounts to the bottom of the outer shell as shown in Figure 2 on the right side as you face 
the unit. Use two (2) 10 - 24 x 3/8” long machine screws and 10 - 24 hex nuts provided.
STEP 3  SQ, KQ, YQ Models - Drill two ¼” holes in outer shell as shown in Figure 3. Also drill a 3/8” 
diameter hole in the base pan 3½” from the back and 3½” from right side.
STEP 4  Small and Medium Chassis Models - Mount in second and third holes from the rear of shell; 
See Figure 4.
STEP 5  Large Chassis Models - Mount in third and fourth holes from the rear of shell; see Figure 5.
STEP 6  Connect a suitable length of garden hose or other tubing to end of the drain tube to drain the 
condensate away.
FIGURE 1
FIGURE 2
FIGURE 3
FIGURE 4
FIGURE 5
RIGHT SIDE
APPROXIMATE 
LOCATION OF 
EMBOSSMENT.  
DRILL 1/2” DIA. 
HOLE
BACK OF BASE PAN
10-24X 3/8” LONG 
SCREWS
DRAIN PLATE
10X24 NUTS
SQ, KQ, YQ MODELS
BOTTOM VIEW
SMALL & MEDIUM
CHASSIS MODELS
BOTTOM VIEW
LARGE
CHASSIS MODELS
BOTTOM VIEW
2ND & 3RD HOLES
FROM REAR OF 
SHELL
3RD & 4TH HOLES
FROM REAR OF 
SHELL
1900235 (11-05)