Wolf PL1912 インストール手順

ページ / 16
MODEL 801640
Page 2
20½"
10
3
/
8
"
8½"
20¾"
7¼"
1¼" 
dia. hole
9
1
/
8
"
Roof   Rafter
REMOVE 
SHINGLES
11" 
dia.
hole
Roof   Rafter
Pilot
Hole
Pilot
Hole
OUTSIDE - ROOF VIEW
"
2"
28¼
"
24¾"
2"
For flat roof installations:
4
  Build a curb that will mount the blower at a minimum pitch of 
2/12. Discharge end of the blower should be pointed away 
from prevailing winds.
 ROOF MOUNT
  INSTALLATION
For use with Models CTWH30, CTWH36, IH4227, W302418-W422418, W302718-W422418, W362210-W482210.
PREPARE THE ROOF
INSTALL THE VENTILATOR
OUTSIDE - ROOF VIEW
OUTSIDE - ROOF VIEW
7 Cover 
Screws
7 Cover 
Screws
Mounting 
Holes
Shipping 
Cardboard
Remove 
roofing 
nails from 
top 2/3 of 
shingles.
Flashing Sheet
Bird Screen
Wiring 
Cover
WIRE THE VENTILATOR
From inside the attic space:
1
  Drill a 
PILOT HOLE up through the roof, 8½" from the inside 
edge of a 
ROOF RAFTER.
From outside - on the roof:
2
  Measure and mark the 20¾" x 20½" rectangle. Cut and 
remove only the shingles inside this rectangle.
3
  Measure and mark the 
11" DIAMETER HOLE and the 1¼" 
DIAMETER HOLE. Cut these holes all the way through the 
roof.
8
 Remove 
SHIPPING CARDBOARD from blower wheel.
9
  Remove roofing nails from top 2/3 of shingles around cut-out 
area.
10
  Slide the ventilator's 
FLASHING SHEET up and under 
the loosened shingles until ventilator's discharge collar 
fits into 11" diameter hole.
11
  Use the 6 screws (provided) to attach the ventilator to the 
roof. 
6 MOUNTING HOLES are provided.
12
  Seal the screw heads, loosened shingles, and edges of 
the flashing sheet, with a good grade of roofing cement.
13
  Check for free movement of the spring-loaded damper, 
re-install 
BIRD SCREEN and ventilator cover. Turn on 
power and check operation.
120 VAC
LINE IN
BLACK
TO
BLACK
WHITE
TO
WHITE
GREEN
TO
GREEN
5
 Remove 
7 COVER SCREWS and lift off ventilator cover. 
Remove 
BIRD SCREEN and WIRING COVER.
6
  Feed the electric power cable through the 
1¼" DIAMETER 
HOLE and connect cable to ventilator with a proper 
connector for the type of cable being used.
Connect 
BLACK TO BLACKWHITE TO WHITE, and the 
GREEN TO GREEN or bare wire. Replace wiring cover.