BEFORE YOU CALL 
CONCERN
CAUSE
SOLUTION
DISPENSER (Ice & Water) (Continued)
Water has an 
odd taste and/
or odor.
•  Water has not been 
dispensed for an 
extended period of time.
•  Unit not properly connected 
to cold water line.
•  Draw and discard 10-12 glasses of water 
to freshen the supply. 
•  Connect unit to cold water line that  
supplies water to the kitchen faucet.
Water pressure 
is extremely 
low.
•  Cut-off and cut-on  
pressures are too low 
(well systems only).
•  Reverse osmosis system 
is in regenerative phase.
•  Have someone turn up the cut-off and cut-
on pressure on the water pump  
system (well systems only).
•  It is normal for a reverse osmosis system to be 
below 20 psi during the regenerative phase.
Water not cold 
enough.
•  As warmer tap water goes 
through the filter and
enters the water tank the 
chilled water is pushed 
through to the dispenser. 
Once the chilled water is 
used up it will take several 
hours to bring the freshly 
replaced water to a cooler 
temperature.
•  Add ice to cup or container before  
dispensing water.
OPENING/CLOSING OF DOORS/DRAWERS
Door(s) will 
not close.
•  Door was closed too 
hard, causing other door 
to open slightly.
•  Refrigerator is not level. 
It rocks on the floor
when moved slightly.
•  Refrigerator is touching 
a wall or cabinet.
•  Close both doors gently. 
 
•  Ensure floor is level and solid, and can
adequately support the refrigerator. Contact a
carpenter to correct a sagging or sloping floor.
•  Ensure floor is level and solid, and can
adequately support the refrigerator. Contact a
carpenter to correct a sagging or sloping floor.
Drawers are 
difficult to 
move.
•  Food is touching shelf 
on top of drawer.
•  Track that drawers slide 
on is dirty.
•  Remove top layer of items in drawer. 
•  Ensure drawer is properly installed on track.
•  Clean drawer, rollers, and track. See Care 
& Cleaning.
RUNNING OF REFRIGERATOR
Compressor 
does not run.
•  Freezer control is set to 
“OF” or “0”.
•  Refrigerator is in defrost 
cycle. 
•  Plug at electrical outlet 
is disconnected.
•  House fuse blown or 
tripped circuit breaker.
•  Power outage.
•  Set freezer control. 
•  This is normal for a fully automatic defrost 
refrigerator. The defrost cycle occurs  
periodically, lasting about 30 minutes.
•  Ensure plug is tightly pushed into outlet. 
•  Check/replace fuse with a 15 amp  
time-delay fuse. Reset circuit breaker.
•  Check house lights. Call local electric 
company.