Electrolux E24RD50QS 仕様シート

ページ / 6
High standards of quality at Electrolux Home Products, Inc.  
mean we are constantly working to improve our products.  
We reserve the right to change specifications or  
discontinue models without notice.
Electrolux Major Appliances, N.A.
USA • 10200 David Taylor Drive • Charlotte, NC 28262   • 1-877-4electrolux (1-877-435-3287) • electroluxicon.com 
CANADA • 5855 Terry Fox Way • Mississauga, ON L5V 3E4 • 1-800-265-8352 • electroluxicon.ca
E24RD50QS 07/14 
© 2014 Electrolux Home Products, Inc.
Under-Counter Refrigerator Drawers
E24RD50QS  professional series
Front
23
7
/
8
"
Power cord 
location (right 
bottom rear)
2
3
/
4
" 3
11
/
32
"
Left
26 
3
/
8
"
33 
3
/
4
"
Adjustable
to 34 
3
/
4
"
21
1
/
2
"
39 
5
/
32
"
23 
23
/
32
"
Drawers fully 
extended  
Refrigerator Drawers - E24RD50QS
Electrolux ICON
Top
23
7
/
8
"
26 
3
/
8
"
24
1
/
8
"
21
3
/
4
"
min.
90°
90°
Recessed 
electrical 
outlet*
*Proper built-in, 
under-counter 
installation requires that 
both electrical outlet & plug 
be completely recessed to ensure 
unit will fit flush against rear wall
 
34"
min.
Under-Counter Refrigerator Drawers Specifications
• 
Product Weight – 165 Lbs.
• 
Voltage  Rating  –120V / 60 Hz / 15  Amps
• 
Connected Load (kW Rating) @ 120 Volts = 0.16 kW 
(For use on adequately wired 120V, dedicated circuit having 2-wire  
service with a separate ground wire. Appliance must be grounded  
for safe operation.)
• 
Amps @ 120 Volts = 1.5 Amps
• 
Electrical cable supplied.
• 
Always consult local and national electric codes.
• 
Unit is designed for built-in, under-counter installation only with use of  
Anti-Tip Kit and can NOT be used in freestanding installation.
• 
Built-in, under-counter installation does not require additional airspace  
for top, sides or rear of unit.
• 
Proper built-in, under-counter installation requires that both electrical  
outlet and plug be completely recessed to ensure unit will fit flush  
against rear wall.
• 
To allow for ease of installation and removal, it is recommended that 
cabinet rough opening dimensions be increased by at least 1/4" over 
product’s dimensions.
• 
For proper ventilation, unit can NOT be installed behind closed doors; front 
grille MUST remain unobstructed.
• 
Must be positioned on flat, level surface, capable of supporting entire 
weight when fully loaded.
• 
Leveling legs supplied to adjust height and level unit.
• 
Do not position unit near any heat source to ensure optimum performance.
• 
Allow 14" minimum for handle clearance with drawers fully extended.
Note:  For planning purposes only. Refer to Product Installation Guide  