Frigidaire FGHB2866PF オーナーマニュアル

ページ / 33
31
BEFORE YOU CALL (CONTINUED)
CONCERN
POTENTIAL CAUSE
COMMON SOLUTION
DISPENSER (Ice & Water)
Dispenser will not 
dispense ice.
•  Dispenser lock out is engaged.
•  There is no ice in the bin to 
be dispensed.
•  The refrigerator doors are 
not completely closed.
•  Dispenser paddle has 
been pressed too long and 
the dispenser motor has 
overheated.
•  Press and hold control lock for three seconds.
•  See the “Ice maker is not making any ice” section 
above.
•  Be sure the refrigerator doors are completely closed. 
•  The motor overload protector will reset in about 
three minutes and then ice can be dispensed.
Ice dispenser is 
jammed.
•  Ice has melted and frozen 
around auger due to infrequent 
use, temperature fluctuations,
and/or power outages.
•  Ice cubes are jammed 
between ice maker and back 
of ice container.
•  Remove ice container, thaw, and empty the contents. 
Clean container, wipe dry, and replace in proper 
position. When new ice is made, dispenser should 
operate.
•  Remove ice cubes that are jamming the dispenser.
Dispenser will not 
dispense water.
•  Dispenser lock out is engaged.
•  Water filter not seated
properly.
•  Water filter is clogged. 
 
•  Household water line valve 
is not open.
•  Press and hold control lock for three seconds.
•  Remove and reinstall the water filter. Be sure to push the
filter firmly so that you hear it lock solidly into position.
•  Replace filter cartridge. Be sure to remove protective
caps and push the filter firmly so that you hear it lock
solidly into position.
•  Open household water line valve. See CONCERN 
column AUTOMATIC ICE MAKER.
Water has an odd taste 
and/or odor.
•  Water has not been dispensed 
for an extended period of time.
•  Unit not properly connected 
to cold water line.
•  Draw and discard 10-12 glasses of water to freshen 
the supply.
•  Connect unit to cold water line that supplies water to 
the kitchen faucet.
Water pressure is 
extremely low.
•  Cut-off and cut-on pressures 
are too low (well systems only).
•  Reverse osmosis system is 
in regenerative phase.
•  Have someone turn up the cut-off and cut-on pressure 
on the water pump system (well systems only).
•  It is normal for a reverse osmosis system to be below 
20 psi during the regenerative phase.
Water not cold enough.
•  As warmer tap water goes 
through the filter and enters
the water tank, chilled 
water is pushed through to 
the dispenser. Once chilled 
water is used up, it will take 
several hours to bring the 
freshly replaced water to a 
cooler temperature.
•  Add ice to cup or container before dispensing water.
OPENING/CLOSING OF DOORS/DRAWERS
Door(s) will not close.
•  Door was closed too hard, 
causing other door to open 
slightly.
•  Refrigerator is not level. 
It rocks on the floor when
moved slightly.
•  Refrigerator is touching a 
wall or cabinet.
•  Close both doors gently. 
 
•  Ensure floor is level and solid, and can adequately
support the refrigerator. Contact a carpenter to 
correct a sagging or sloping floor.
•  Ensure floor is level and solid, and can adequately
support the refrigerator. Contact a carpenter to 
correct a sagging or sloping floor.
Drawers are difficult to
move.
•  Food is touching shelf on 
top of drawer.
•  Track that drawers slide on 
is dirty.
•  Remove top layer of items in drawer.
•  Ensure drawer is properly installed on track.
•  Clean drawer, rollers, and track. See Care & Cleaning.