Broan B56 仕様シート

ページ / 2
Broan-NuTone LLC    Hartford, Wisconsin    www.broan.com    800-558-1711
B56 & B57 SERIES WIRING 
B56 & B57 SERIES MOUNTING
NOTES: 
1.  Minimum hood distance above cooktop must not be less than 30”.
 A maximum of 36” above the cooktop is highly recommended for best capture of cooking impurities.
 Distances over 36” above the cooktop are at the installer’s and user’s discretion - providing that ceiling height and flue length permit.
8¼”
MAX.
1. GROUNDING INSTRUCTIONS
This appliance must be grounded. In the event of an electrical short circuit, grounding 
reduces the risk of electric shock by providing an escape wire for the electric current. This 
appliance is equipped with a cord having a grounding wire with a grounding plug. The plug 
must be plugged into an outlet that is properly installed and grounded.
2. Position  the  electrical  outlet  within  the  space  covered  by  the  decorative  flue  and 
where  it  will  not  interfere  with  the  round  duct.  Make  sure  the  outlet  is  no  further 
than  8¼”  from  where  the  cord  exits  from  the  hood  and  that  the  outlet  does  not 
interfere with a mounting bracket fastening area or where the decorative flue touches the wall. 
C
L
1. Construct wood wall framing that is flush with interior surface of wall studs.
Make sure:
a)  the framing is centered over installation location.
b)  the height of the framing will allow the mounting bracket 
to be secured to the framing within the dimensions  
 
shown.
2. After wall surface is finished, carefully center and level the hood 
mounting bracket and secure it to wall framing with (3) #8 x 1-1/2” 
mounting screws. Tighten the screws completely.
NOTE:
On 8-ft. ceilings
Hood distance above cooktop is:
Minimum 30”, Maximum 36” (for ducted discharge)
Minimum 30”, Maximum 33” (for non-ducted discharge)
On 9-ft. ceilings
Hood distance above cooktop is:
Minimum 31”, Maximum 36” (for both ducted and non-ducted 
discharge)
On 10-ft. ceilings
Hood distance above cooktop is:
Minimum 31”, Maximum 36” (for both ducted and non-ducted 
discharge).
NOTE: 10-ft. ceilings require 10-ft. Flue Extension, Model FXN56SS 
for ducted or non-ducted installations (purchase separately).
9
42
1
2
” = bottom of hood 30” above cooktop
48
1
2
” = bottom of hood 36” above cooktop
4
1
2
FRAMING BEHIND  
DRYWALL
WALL STUDS
MOUNTING BRACKET 
LOCATION 
(ABOVE 36” HIGH 
COOKTOP)
CEILING
DUCT
HOOD DISTANCE ABOVE 36” COOK TOP (SEE NOTE 1)
HEIGHT
METHOD
30”
31”
32”
33”
34”
35”
36”
MOUNTING BRACKET LOCATION ABOVE 36” HIGH COOK TOP
8 FEET
DUCTED
42-1/2”
43-1/2”
44-1/2”
45-1/2”
46-1/2”
47-1/2”
48-1/2”
NONDUCTED
42-1/2”
43-1/2”
44-1/2”
45-1/2”
9 FEET
DUCTED OR
43-1/2”
44-1/2”
45-1/2”
46-1/2”
47-1/2”
48-1/2”
NONDUCTED
10 FEET
DUCTED OR
NONDUCTED
43-1/2”
44-1/2”
45-1/2”
46-1/2”
47-1/2”
48-1/2”
WITH FXN56SS