Zephyr BMIE36 入門ガイド

ページ / 24
=
Duct  pieces 
Total
Equivalent  number
length  x used       =
3- 1/ 4” x 10”
Rect.,
straight
1 Ft.           x (      )   =
Ft.   
8” Round,
straight
1 Ft.           x (      )   =
Ft.   
3- 1/ 4” x 10”
Rect. 90
0
elbow
15 Ft.         x (      )   =
Ft.   
3- 1/ 4” x 10”
Rect. 45
0
elbow
9 Ft.           x (      )   =
Ft.   
3- 1/ 4” x 10”
Rect. 90
0
flat elbow
24 Ft.         x (      )   =
Ft.   
3- 1/ 4” x 10”
Rect.
wall cap
with damper
30 Ft.         x (      )   =
Ft.   
3- 1/ 4” x 10”
Rect. to
6” round
transition
5 Ft.           x (      )   =
Ft.   
3- 1/ 4” x 10”
Rect. to
6” round
transition
90
0  
elbow
20 Ft.         x (      )   =
Ft.   
6” Round,
90
0  
elbow
15 Ft.         x (      )   =
Ft.   
6” Round,
45
0  
elbow
9 Ft.           x (      )   =
Ft.   
Ft.   
7” Round,
straight
1 Ft.           x (      )   =
Ft.   
Subtotal column 1 =
Duct  pieces 
Total
Equivalent  number
length  x used       =
6”- 8” Round
wall cap
with damper
30 Ft.         x (      )   =
Ft.   
Round
wall cap
with damper
30 Ft.         x (      )   =
Ft.   
7” or 8” 
Round,
90
0  
elbow
15 Ft.         x (      )   =
Ft.   
7” or 8” 
7” or 8” 
Round,
45
 
elbow
9 Ft.           x (      )   =
Ft.   
Ft.   
Ft.   
Ft.   
6”- 8” Round,
roof cap
30 Ft.         x (      )   =
Ft.   
7” or 8”
Round,
roof cap
30 Ft.         x (      )   =
Ft.   
Subtotal column 2 =
Subtotal column 1 =
Total ductwork      =
Maximum Duct Length: 
For satisfactory air movement,
the total duct length of a 3 1/ 4” x 10” rectangular  6” or 7”
diameter round duct should not exceed 100 equivalent feet.
6” round to
3- 1/ 4” x 10”
rect. 
transition
1 Ft.           x (      )   =
Ft.   
6” round to
3- 1/ 4” x 10”
rect. 
transition
90
0  
elbow
16 Ft.         x (      )   =
Ft.   
7” round to
3 1/ 4” x 10”
rect. 
transition
8 Ft.           x (      )   =
Ft.   
7” round to
3- 1/ 4” x 10”
rect. 
transition
90
0  
elbow
23 Ft.         x (      )   =
Ft.   
   >
(/  8/  3