Open service access door and check that the fan’s impeller is moving freely before making electrical 
connection. The fan is designed for mounting at any angle, but the unit should be mounted so that 
the hinged blower access panel is exposed for any potential maintenance.Select an easily accessible 
location in the planned duct run. Keep in mind that for 
optimum performance the blower should be located 
after all turns and as close as possible to exterior 
wall so that a straight run is afforded for discharge 
to the outside. For long duct runs and applications 
where the blower cannot be at the end of the duct 
run, use of a larger duct is recommended. Transi-
tions allow the fan to be installed to a round duct. For 
sealing the transitions to the blower housing, attach 
the rubber strips provided with unit prior to installa-
tion. Removal of transitions allows for installation to 
square/rectangular ducting. The housing should be 
hung using metal strapping or fixed mounting brack-
ets (not supplied). The housing should be insulated 
from the structure by rubber padding (not supplied) 
to eliminate any potential vibration. Unit requires a 15 
amp dedicated circuit at 115 volts. (ELECTRICAL CONNECTIONS SHOULD ONLY BE MADE BY 
A LICENCES ELECTRICIAN) The electrical connection is completed by feeding the wires from the 
switched 120-volt source (hood or accessory switch) to the electrical junction box located on the top 
of the service access door using proper strain release and grommets to prevent chafing. Connect 
the Live (Black) Wire to the Live (Black) Wire on a switched 120-volt AC Source. Connect the Neutral 
(White) wire to the Neutral (White) wire of the 120-volt AC Source (as seen on Diagram A on following 
page.)  Unit should be tested to ensure that the hook up is correct and the unit is functioning properly 
before finalizing installation.
 *Note - Optional Wall Switch (model # UIBWSK) is available for all 
Prestige Ventilation. 
(See your salesperson for more information.)
- 1 -