Viking FGIM515 インストール手順

ページ / 10
17
16
Gravity Drain Pump Model drain installation
1. Place the ice machine in front of the installation opening. Adjust leveling legs to the approximate height.
2. Remove the front service access panel and the upper back panel (if necessary).
Note: If you are connecting a gravity drain model and the drain opening has been located in the floor under the base
pan according to the pre install specifications, follow steps 3 through 5 to drain the unit through the base. If not,
proceed to step 6b.
3. Remove the clamp and barbed elbow and take off the plastic cover in the base pan below the drain hose.
4. Connect a straight 5/8” barbed connector to the drain hose, securing with the clamp removed in step 4.
5. Cut an 8” piece of 5/8” ID X 7/8” OD tygon (clear plastic) tubing. Slide one end of the tube onto the outlet of the
barbed connector and secure with a clamp. Leave the other end of the tube lying on the floor of the base pan until
the unit is positioned over the floor drain.
6. Route the drain tube. Either a) Insert the drain tube through the base pan into the floor drain or b) Route the drain
tube through the left hole in the lower back panel and connect to barbed elbow and secure with a clamp.
7. Reinstall the upper back panel (if removed in step 2).
8. Reinstall the service access panel. Level the unit.
Back View, Gravity Drain Model
Water Inlet
Tube (field
supplied)
Drain Hose
Barbed Elbow
Drain Hose,
Route to
building drain
CAUTION
Restrictions in the drain system to the machine will cause water to back up into the ice storage bin and melt the ice. Gravity drain tubing
must be vented, have no kinks and slope to the building drain. Air gaps are typically required by local code.
WATER & DRAIN INSTALLATION
The recommended water supply tubing is 1/4” OD copper. Stainless steel flex or reinforced PVC tube may also be
used. Install an easily accessible shut-off valve between the supply and the unit. This shut-off valve should not be
installed behind the unit.
Note: DO NOT use self-piercing type valves.
1. Remove the front service access panel by removing the screw.
2. Route the tubing through the right hole in the back to the inlet water
solenoid valve inlet.
3. Install a compression fitting on the tubing and connect to the inlet of the
solenoid (fitting is located in cloth bag behind access panel).
DRAINS
There are two types of ice machine models, one that drains by gravity and
one that has an internal drain pump.
Drain Pump Model drain installation
1. Locate the coil of 3/8” ID plastic drain tubing secured to the back of the unit.
2. Route the plastic drain tube from the back of the unit to the drain connection point.
IMPORTANT NOTE: Often an air gap is required by local codes between the ice maker drain tube and the drain
receptacle.
Screw
Service
Access 
Panel
Back View, Drain Pump Model
Water Inlet
Tube (field
supplied)
Drain Tube,
Route to
building drain