Frigidaire FFVU17F4QW 図

ページ / 2
PERFORMANCE DATA NO LOAD & NO DOOR OPENINGS AT MID-POINT                           
CONTROL SETTING
Capacitor Run or 
Induction Run
70°F (21°C) Ambient
90°F (32°C) Ambient
Operating Time
40 to 50%
55 to 65%
Freezer Temperature
-3° to 3° F  
-19° to -16° C
-3° to 3° F  
-19° to -16° C
Low Side Pressure  
(cut-in)
6 to 12 psig  
41 to 83 kPa
6 to 12 psig  
41 to 83 kPa
Low Side Pressure      
(cut-out)
-1 to 3 psig  
-4 to 21 kPa
-1 to 3 psig  
-4 to 21 kPa
High Side Pressure               
(last 1/3 cycle)
85 to 100 psig  
575 to 670 kPa
120 to 135 psig  
810 to 910 kPa
Wattage (last 1/3 cycle)
100 to 120
110 to 130
Amps (running)
.9 to 1.1
1.0 to 1.2
Base Voltage
115 vac (127 vac max)
DEFROST SPECIFICATIONS
Cabinet Size
Thermostat
Heater
Cut-in
Cut-out
Watts
Ohms
19’
21° F (-6° C)
42° F (6° C)
550
24
Electronic Timer - Defrost 30 minutes every 12 hours of compressor run time.
CONDENSER FAN MOTOR
Watts
RPM
Amps
2.3
1100 CW Opposite Shaft
0.13 Running
ICE MAKER SPECIFICATIONS
Electrical
115 vac (127 vac max) 60 Hertz
Thermostat
Opens at 48° F ( 9° C), Closes at 15° F ( -9° C)
Models with orange wire close at 8.96° F (-12.8° C)
Heater Wattage
165 
ICE MAKER CONNECTOR PLUG CONNECTIONS
Wire Number
Wire Color
Connects to:
1
Green/Yellow
Ground
2
Yellow
Water Valve
3
Black
Line
4
Light Blue
Neutral
IMPORTANT: PLEASE RETURN THIS SHEET TO IT’S 
ORIGINAL LOCATION
ICE MAKER INFORMATION
Test Cycling
Remove  cover  by  inserting  screwdriver  in  notch  at    bottom  and 
prying cover from housing. Use screwdriver to rotate motor gear 
counterclockwise  until  holding  switch  circuit  is  completed.  All 
components of ice maker should function to complete the cycle.        
TUR
N
Mounting
Plate
Screws
Mounting
Plate
Screw
Motor
Gear
Timing
Gear
Water Fill
Adjustment
Water Fill Volume
The water fill adjustment 
screw  will  change  the 
fill  time.  One  full  turn  is 
equal  to  20cc  (.68  oz.). 
The  correct  fill  is  95  to 
105cc  (3.2  to  3.6  oz.). 
When  a  water  valve  is 
replaced,  the  fill  volume 
must be checked.
SERVICE DATA SHEET  -   297299800
STANDARD - AUTOMATIC DEFROST  FREEZER
MODELS (
R134a)
IMPORTANT SAFETy NOTICE
The information provided herein is designed to assist qualified 
repair personnel only. Untrained persons should not attempt to 
make repairs due to the possibility of electrical shock. Disconnect 
power cord before servicing.
IMPORTANT
If  any  green  grounding  wires  are  moved  during  servicing, 
they  must  be  returned  to  their  original  position  and  properly 
secured.
 
CAUTION:
 
All  electrical  parts  and  wiring  must  be 
shielded from torch flame. Do not allow torch to contact 
insulation; it will char at 200°F.
NOTE:
 
Products  come  equipped  with  an  Electronic  Defrost 
Control. To initiate defrost, press and hold air filter and alarm 
reset key simultainiously for three seconds.  To terminate defrost, 
press and hold air filter and alarm reset key simultainiously for 
three seconds
POWER
ICE MAKER
IC
E M
AKE
R
I
CE MAKER
ICE MAKER
WATER VALVE
LINE
THER MAL
CUT-OUT
HOLD
SW ITCH
T HERMOSTAT
SHUT-OF F
SWITCH
WATER FILL
SWITCH
MOLD  HEATER
MOLD
MOUN TING
PLATE
MOTOR
NEUT RAL
BLK
BLK
B LK
BLK
BLU
LT. BLU
LT. BLU
BRN
RED
GRN  / yEL
GRN / yEL
RED
YEL
YEL
YEL
P-3
P-1
P-2
P-4