INSTALLATION  
(cont’d): 
WARNING: ELECTRICAL SHOCK HAZARD! 
Use extreme caution when drilling holes into the wall or floor. There may be concealed electrical wires located behind the wall or 
under the floor. 
Identify the electrical circuits that could be affected by the installation of the Anti-Tip Device, then turn off power to these circuits.
 
Failure to follow these instructions may result in electrical shock or other personal injury. 
CAUTION: PROPERTY DAMAGE! 
Contact a qualified installer or contractor to determine the proper method for drilling holes through the wall or floor material (such 
as ceramic tile, hardwood, marble, etc.) 
DO NOT slide range across unprotected floor. 
Failure to follow these instructions may result in damage to wall or floor coverings. 
STEP 5: GAS CONNECTION AND HOOK -UP 
 
PLEASE NOTE: 
In the Commonwealth of Massachusetts, gas connection must be performed by a licensed plumber or licensed 
gas fitter.
 
NOTE:  Capital  DOES  NOT  supply  ranges  to  match  varying  altitudes.  Orifices  to  adjust  for  combustion  for  differing 
altitudes may be purchased through Capital Cooking Equipment by calling our Parts Department at 1-866-4024600, 
or email us at customerservice@capital-cooking.com.
 
 
Verify the type of gas being used at the installation site matches the gas type of the range. As shipped from the factory, units 
are configured for use with  Natural Gas or Propane (LP). Make certain the range matches the  type  of  gas  available at the 
location. 
For  installation  of  the  appliance  at  high  altitude,  please  consult  your  local  gas  company  for  their  recommendation of the 
correct orifice sizes and any other necessary adjustments that will provide proper gas combustion at specified altitudes. 
PROPANE (LP) GAS REQUIREMENTS: 
Inlet Connection: 1/2" N.P.T. 
Min. 5/8" Dia, Flex Line. 
Supply Pressure: 11" to 14" W.C. 
A Regulator is required at the LP source to provide a maximum of 14" W.C. pressure to the range regulator.
 
NATURAL GAS REQUIREMENTS:
 
Inlet Connection: 1/2" N.P.T. 
Min. 5/8" Dia. Flex Line. 
Supply Pressure: 6" to 14" W.C. 
The open top burner flames should be approximately 1" to 1-1/4" High. 
 
GAS HOOK UP
 
WARNING!  Gas line cannot  be  run inside  back  cover  of  range.  Run gas  line  in  channel in  back 
of range.
 
CAUTION!  A  qualified  technician  must  make  burner adjustments  at  the time of installation. 
Improper or lack of adjustments may cause harmful by-products or void your warranty!
 
TESTING AND ADJUSTMENTS 
Install any loose components, such as burner caps and grates, oven racks that may have been removed earlier to facilitate 
moving  the  appliance.  Be  certain  that  burner  caps  seats  properly  into  the  alignment  slots  in  the  burner  bases.  Before 
testing operation of the appliance, verify that the unit and the gas supply have been carefully checked  for leaks and that 
the  unit  has  been  connected  to  the  electrical  power  supply.  Turn  the  manual  gas  shut-off  valve  to  the  open  position. 
Check  the  operation  of  the  sealed  gas  burners  by  pushing  and  turning  each  knob  counterclockwise  to  "Hl".  The 
burner  igniters  will  click  until  the  flame  ignites.  Burner  flames  should  be  BLUE  and  stable  with  no  yellow  tips, 
excessive noise, or lifting of the  flame from the burner. If any of these conditions exist, check that the air shutter (grill 
and griddle only) or burner ports are not blocked or clogged.  Remove any blockages that exist. If the flame is too yellow, 
indicating insufficient air, adjust the shutter counterclockwise to increase air inlet (grill and  griddle only).