Friedrich WY09D33 インストール手順

ページ / 2
CAUTION:  Bodily injury can be caused by louvers 
falling from a building during installation. It is 
recommended  that  a  safety  line  be  attached 
to the louver and to an anchor point inside the 
building during installation.
4.  Grasp  the  louver  by  the  attached  plastic  handles.
Position it with the condensate drain knockouts fac-
ing down. From inside the building, maneuver the
louver through the wall sleeve and pull it toward you
until the screw heads are inserted into the keyhole
slots at the top of the wall sleeve. Tighten the two
screws completely.
5.  Insert the remaining screws into the remaining holes
and tighten securely.
Installation
1.  Remove the center support and weatherboard if still
installed in the sleeve.
2.  Insert six plastic grommets into the louver openings
from the outside of the louver as shown in Figure 2.
3.  Insert two #8 x 3/8” sheet metal screws (provided)
in the top two outside edge plastic grommets, and
tighten them half way into the grommets.
Parts List - Standard Louver
Description
Stamped Aluminum Louver
Plastic Grommets
#8 x 3/8" Sheet Metal Screws
Figure 1
Quantity
1
6
6
Figure 2
920-122-00 (3-07)
Grommet
Stamped 
Louver
Knockout For 
Drain Opening
Wall Sleeve
Plastic Handles
#8 x 3/8" 
Sheet 
Metal 
Screw
Stamped 
Louver
Installation Instructions
STANDARD LOUVER
For Use With Packaged Terminal Units
Please read these instructions completely before attempting installation.
NOTE:  These instructions apply to the Packaged Terminal Unit Standard Louver Installation Kit ONLY. Refer to chassis
Installation/Operation manual and Wall Sleeve Installation Instructions for additional information.
Check box for parts listed in Figure 1.
Model PXGA