Electrical system requirements
Water supply requirements
Grounding requirements
Drain system requirements
CIRCUIT -  Individual, properly polarized and 
grounded 15 amp. branch circuit fused with 15 
amp. time delay fuse or circuit breaker.
POWER SUPPLY - 2 wire, with ground, 120 volt 
single phase, 60 Hz, Alternating Current.
OUTLET RECEPTACLE - Properly grounded 
3-prong receptacle to be located so the power 
supply cord is accessible when the washer is in 
an installed position.
Grounding type
Grounding type
wa
wall receptacl
ll receptacle
Po
Power cord with
wer cord with
3-prong 
3-prong  gr
grounded plug
ounded plug
Do not,
Do not, under
under
an
any cir
y circumstances,
cumstances,
cut,
cut, remo
remove
ve,
or b
or bypass th
ypass the
gr
grounding pr
ounding prong.
ong.
Installation Requirements
       NOTE
Because of potentially inconsistent voltage 
capabilities, the use of this washer with power 
created by gas powered generators, solar 
powered generators, wind powered generators 
or any other generator other than the local utility 
company is not recommended.
       NOTE
Drain hose attached to the washer can reach a 79 
in. (201 cm) high standpipe. For higher standpipe,  
use hose P/N 137098000, available from an 
authorized parts distributor. 
       NOTE
GFI (Ground Fault Interrupter) receptacle is not 
required.
       WARNING
ELECTRICAL SHOCK HAZARD
Improper connection of the equipment grounding 
conductor can result in a risk of electrical shock. 
Check with a licensed electrician if you are in doubt 
as to whether the appliance is properly grounded.
1.  The washer MUST be grounded. In the event 
of malfunction or breakdown, grounding will 
reduce the risk of electrical shock by a path of 
least resistance for electrical current.
2.  Since your washer is equipped with a power 
supply cord having an equipment-grounding 
conductor and a grounding plug, the plug 
MUST be plugged into an appropriate, copper 
wired receptacle that is properly installed and 
grounded in accordance with all local codes and 
ordinances or in the absence of local codes, 
with the National Electrical Codes, ANSI/NFPA 
70 (latest edition). If in doubt, call a licensed 
electrician. DO NOT cut off or alter the grounding 
prong on the power supply cord. In situations 
where a two-slot receptacle is present, it is 
the owner’s responsibility to have a licensed 
electrician replace it with a properly grounded 
three prong grounding type receptacle.
Hot and cold water faucets MUST be installed 
within hose length of your washer’s water inlet. The 
faucets MUST be 3/4 inch (1.9 cm) with thread-
ing for laundry hose connection. Water pressure 
MUST be between 30 and 120 psi. Pressure differ-
ence between hot and cold cannot be more than 
10 psi. Your water department can advise you of 
your water pressure.
1.  Drain capable of eliminating 17 gals (64.3 L) per 
minute.
2.  A standpipe diameter of 1-1/4 in. (3.18 cm) 
minimum. 
3.  The standpipe height above the fl oor should be:
Minimum height:   24 in. (61 cm)
Maximum height:  96 in. (244 cm)
96”
(244cm)
max.
24”
(61cm)
min.