Amana AGR4433XDB インストール手順

ページ / 28
6
Flexible metal appliance connector:
If local codes permit, a new CSA design-certified, 
4 to 5 ft (122 to 152.4 cm) long, ½" (1.3 cm) or 
¾" (1.9 cm) I.D., flexible metal appliance connector may 
be used for connecting range to the gas supply line. 
A ½" (1.3 cm) male pipe thread is needed for connection 
to the female pipe threads of the inlet to the appliance 
pressure regulator.
Do not kink or damage the flexible metal tubing when 
moving the range.
Rigid pipe connection: 
The rigid pipe connection requires a combination of pipe 
fittings to obtain an in-line connection to the range. The rigid 
pipe must be level with the range connection. All strains must 
be removed from the supply and fuel lines so range will be 
level and in line.
Must include a shutoff valve: 
The supply line must be equipped with a manual shutoff valve. 
This valve should be located in the same room but external to 
the range. It should be in a location that allows ease of 
opening and closing. Do not block access to shutoff valve. 
The valve is for turning on or shutting off gas to the range.
Gas Pressure Regulator
The gas pressure regulator supplied with this range must be used. 
The inlet pressure to the regulator should be as follows for proper 
operation:
Natural gas:
Minimum pressure: 5" WCP
Maximum pressure: 14" WCP
LP gas:
Minimum pressure: 11" WCP
Maximum pressure: 14" WCP
Contact local gas supplier if you are not sure about the inlet 
pressure.
Burner Input Requirements
Input ratings shown on the model/serial rating plate are for 
elevations up to 2,000 ft (609.6 m). 
For elevations above 2,000 ft (609.6 m), ratings are reduced at a 
rate of 4% for each 1,000 ft (304.8 m) above sea level (not 
applicable for Canada). 
Gas Supply Pressure Testing
Gas supply pressure for testing regulator must be at least 
1” water column pressure above the manifold pressure shown on 
the model/serial rating plate.
Line pressure testing above ½ psi gauge (14" WCP)
The range and its individual shutoff valve must be disconnected 
from the gas supply piping system during any pressure testing of 
that system at test pressures in excess of ½ psi (3.5 kPa).
Line pressure testing at ½ psi gauge (14" WCP) or lower
The range must be isolated from the gas supply piping system by 
closing its individual manual shutoff valve during any pressure 
testing of the gas supply piping system at test pressures equal to 
or less than ½ psi (3.5 kPa).
INSTALLATION INSTRUCTIONS
Unpack Range
1. Do not use oven door handle to lift or move the range
2. Remove shipping materials, tape and film from range. Keep 
cardboard bottom under range. 
3. Remove oven racks and parts package from inside oven.
4. To place range on its back, take 4 cardboard corners from the 
carton. Stack one cardboard corner on top of another. Repeat 
with the other 2 corners. Place them lengthwise on the floor 
behind the range to support the range when it is laid on its 
back. 
5. Using 2 or more people, firmly grasp the range and gently lay 
it on its back on the cardboard corners.
6. Pull cardboard bottom firmly to remove.
7. Use an adjustable wrench to loosen the leveling legs. Adjust 
the leveling legs to the correct height. Leveling legs can be 
loosened to add up to a maximum of 1" (2.5 cm). A minimum 
of 
³⁄₁₆" (5.0 mm) is needed to engage the anti-tip bracket.
NOTE: If height adjustment is made when range is standing, tilt 
the range back to adjust the front legs, then tilt forward to adjust 
the rear legs.
8. Place cardboard or hardboard in front of range. Using 2 or 
more people, stand range back up onto cardboard or 
hardboard.
A. Gas supply line
B. Shutoff valve “open” position
C. To range
A
B
C
WARNING
Excessive Weight Hazard
Use two or more people to move and install range.
Failure to do so can result in back or other injury.